Loading...
HomeMy WebLinkAbout2025 - Richmond Community Water System Richmond Community Drinking Water System Waterworks#2600074854 System Category—Small Municipal Year-Round Residential Annual Water Report Prepared For: The Municipality of Bayham Reporting Period of January 1st — December 31s' 2025 Issued: February 26th, 2026 Revision: 0 Operating Authority: OCWA ONTARIO CLEAN WATER AGENCY v AGENCE ONTARIENNE DES EAUX This report has been prepared to satisfy the annual reporting requirements in 0. Reg 170/03 Section 11 and Schedule 22 Ontario Clean Water Agency—Richmond Community Drinking Water System—2025 Annual Water Reports Table of Contents Annual Summary Report..........................................................Error! Bookmark not defined. RevisionHistory ............................................................................................................7 ReportAvailability.........................................................................................................7 System Process Description........................................................................................7 SourceWater and Wells.......................................................................................................................7 TreatmentProcess................................................................................................................................7 Treatment Chemicals used during the reporting year......................................................................................8 Compliance.....................................................................................................................8 Adverse Water Quality Incidents..........................................................................................................9 Non-Compliance...................................................................................................................................9 Non-Compliance Identified in a Ministry Inspection............................................................................9 Flows............................................................................................................................. 10 Raw/Treated Water Flows..................................................................................................................10 Ontario Clean Water Agency—Richmond Community Drinking Water System—2025 Annual Water Reports Revision History Table 1. Revision History Date Revision# Revision Notes 02/26/2026 0 Report Issued Report Availability This summary report for the Richmond Community Drinking Water System (DWS) is published in accordance with Schedule 22 of Ontario's Drinking Water Systems Regulation for the reporting period of January 1"to December 31St, 2025.This system does not serve more than 10,000 residence and the annual reports will be available to residents at the Municipal Office as well as on the municipal website. Notification will be at the Municipal Office and copies provided free of charge if requested. This report was prepared by the Ontario Clean Water Agency on behalf of the Municipality of Bayham and must be supplied to the Bayham Municipal Council by March 31, 2026. System Process Description Source Water and Wells Three (3) production wells are connected to the system: one bedrock well (TW1-10) and two overburden wells (TW2-12 and TW3-12). Under normal operation, one overburden well operates at a time.The bedrock well is maintained but is not typically used due to aesthetic concerns. All three wells are classified by the Ministry as Groundwater Under the Direct Influence of Surface Water(GUDI) without effective in-situ filtration. Treatment Process Raw water from the wells enters the treatment building through separate piping for the bedrock and overburden sources and then combines into a common raw water header. Due to elevated nitrate levels in the overburden wells,treatment includes water softening and nitrate removal using ion exchange prior to storage.A nitrate analyzer on the common raw water header is used to monitor treatment effectiveness and support operational control. Primary disinfection is achieved using ultraviolet(UV) disinfection and sodium hypochlorite,which is dosed upstream of the storage tanks to provide adequate contact time.Treated water is conveyed to two on-ground storage tanks, one equipped with a top spray bar for aeration and the other with a bottom discharge connection. High-lift booster pumps draw water from storage and convey it through the treatment process. Prior to UV disinfection, water passes through parallel cartridge filters to provide equivalent in-situ filtration. Secondary disinfection is maintained using sodium hypochlorite downstream of the UV system to preserve a disinfectant residual throughout the distribution system Ontario Clean Water Agency—Richmond Community Drinking Water System—2025 Annual Water Reports Treatment Chemicals used during the reporting year Sodium hypochlorite is used to achieve Primary and Secondary disinfection in the Richmond Community Drinking Water System. Refer to Table 2 for treatment chemical supplier information of which are NSF60 approved for use in drinking water. Table 2. Treatment Chemicals utilized at Richmond Community DWS Chemical Name Use Supplier Sodium Hypochlorite Disinfection Nevtro Sales Compliance The Richmond Community DWS was operated and maintained in such a manner that treated water supplied to the consumers serviced by the system satisfied the Ontario Drinking Water Quality Standards. On January 1St, 2026 OCWA began operating the Richmond Community Drinking Water System. Notification was provided to the MECP on November 25th, 2025. OCWA was granted limited scope transitional accreditation on December 41h, 2025 and will be seeking full scope accreditation in 2026. Table 3. Compliance Report Card Compliance Event Date #of Events Ministry of Environment January 5th, 2025 N/A Inspections Ministry of Labour N/A 0 Inspections October 3rd, 2025 9 QEMS External Audit November 25th,2025 2 AWQI's/BWA September 17th, 2025 1 Non-Compliance N/A 0 Community Complaints N/A 0 Spills N/A 0 Watermain Breaks N/A 0 Ontario Clean Water Agency—Richmond Community Drinking Water System—2025 Annual Water Reports Adverse Water Quality Incidents Under the Safe Drinking Water Act, O.Reg 170/03, any adverse water quality incidents (AWQI) are required to be reported to the Ministry of the Environment, Conservation and Parks (MECP) and corrective action taken. Refer to Table 4 below for a summary of AWQI incidents in 2025. Table 4: AWQI Incidents Date AWQI# Location Problem Details Legislation Corrective Action Taken Loss of pressure in Pumps shut off as a safety Richmond the distribution O. Reg. Low measure.CT calculation was 09-17-25 169947 Distribution system due to the 170/03— System Pressure in-line boosters performed and CT was shutting off Schedule 16 maintained in the holding tanks Non-Compliance Under the Safe Drinking Water Act, O. Reg 170/03, any events where legislative requirements were not met are required to be reported to the MECP and corrective actions taken. Refer to Table 5 below for a summary of non-compliance incidents in 2025. Table S: Non-Compliance Incidents requirement(s)system failed duration of the failure Legislation Corrective Action Status to meet (i.e.date(s)) There were no non-compliance issues reported during the reporting period. Non-Compliance Identified in a Ministry Inspection The annual routine inspection of the Richmond Community Drinking Water System occurred on January 51", 2026, and was conducted by Provincial Officer,Jim Miller of the Ministry of the Environment, Conservation and Parks (MECP). The final report has not yet been received. The routine MECP Inspections have an Inspection Rating Record, which evaluates the system to provide information for the owner/operator on areas that need to be improved. The particular areas that were evaluated for the Richmond Community Drinking Water Supply System were: Treatment Process, Operations Manuals, Logbooks, Certification and Training,Water Quality Monitoring, and Reporting and Corrective Actions. There were no issues or concerns to report in 2025 that required corrective action for the Richmond Community Drinking Water System. Table 6: Non-Compliance from Ministry Inspections requirement(s)system failed duration of the failure Legislation Corrective Action Status to meet (i.e.date(s)) There were no non-compliances identified during this period. Ontario Clean Water Agency—Richmond Community Drinking Water System—2025 Annual Water Reports Major Maintenance Summary Distribution Maintenance Table 7:Maintenance Details - Hydrant flushing - Valve turning - Flow meter calibrations - Operating: $106,234 Flows Raw/Treated Water Flows The Richmond Community DWS is categorized as a Small Municipal Residential Drinking Water System. The system is supplied by groundwater from three municipal wells and provides treated water to consumers within the Village of Richmond. The Richmond Community DWS operated in accordance with the Municipal Drinking Water Licence 061- 102 and Drinking Water Works Permit 061-202. In accordance with Schedule 22-2(3) below is a summary and discussion of the quantity of water supplied during the reporting period. The water that is treated is regulated under the Municipal Drinking Water Licence#061-102, in which the rated capacity for the system is 43.2m3/d. The Richmond Community Drinking Water System East Train is operating at 36.5%and the West Train is operating at 39.2%of the rated capacity. The raw and treated flows are one in the same as there are only the two treated water flowmeters for each train. Refer to Figure 1 for the average daily flow each month. Figure 1: Average Daily Flow Each Month 50 v 40 3 30 0 20 10 0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Avg Month 2025 East Average Daily Flow(m3/d) 2025 West Average Daily Flow(m3/d) Rated Capacity(m3/d) Figure 1:Average Daily Flows each Month Ontario Clean Water Agency—Richmond Community Drinking Water System—2025 Annual Water Reports Appendix A contains monthly flow readings from the East and West Trains within the Richmond Community DWS. Appendix A Summary of flow volumes to the Richmond Community Drinking Water System East&West Train from 2021-2025(values in m3 unless indicated) Jan. Feb. March April May June July Aug. Sept. Oct. Nov. Dec. Totals 490 405 424 371 489 551 582 544 490 468 462 484 5760 16 14 14 12 16 18 19 18 16 15 15 16 528 415 436 406 523 590 622 581 524 501 496 517 6139 17 15 14 14 17 20 20 19 17 16 17 17 1 446 390 463 465 500 486 494 498 517 578 535 547 5919 14 13 15 16 16 16 16 16 17 19 18 18 441 431 447 470 533 518 540 533 552 615 575 588 6243 �C1U� 14 15 14 16 16 17 17 17 18 20 19 19 474 491 493 496 543 525 457 458 459 446 430 448 5720 15 18 16 17 18 18 15 15 15 14 14 14 498 505 526 527 454 442 434 422 425 427 416 430 5506 16 18 17 18 15 15 14 14 14 14 14 14 399 354 392 413 376 475 438 423 430 437 467 422 5026 12 12 12 13 12 15 14 13 14 13 15 13 409 342 402 424 386 485 451 436 443 449 480 433 5140 �Y1L'� 13 12 13 14 13 16 15 14 15 14 16 14 415 368 403 400 452 489 459 456 447 456 453 472 5270 13 13 13 13 15 16 15 15 15 15 15 15 426 376 413 411 463 500 472 470 460 469 465 484 5409 �i'' 14 13 13 14 15 17 15 15 15 15 16 16 rr� (ir Ontario Drinking-Water Systems Regulation O. Reg. 170/03 OPTIONAL ANNUAL REPORT TEMPLATE Drinking-Water System Number: 260074854 Drinking-Water System Name: Richmond Community Drinking Water System Drinking-Water System Owner: The Corporation of the Municipality of Bayham Drinking-Water System Category: Small Municipal Year Round Residential Period being reported: 2025 Complete if your Catezory is Lame Municipal Complete for all other Catezories. Residential or Small Municipal Residential Does your Drinking-Water System serve Number of Designated Facilities served: more than 10,000 people? Yes [ ] No [ x] N/A Is your annual report available to the public Did you provide a copy of your annual at no charge on a web site on the Internet? report to all Designated Facilities you Yes [ x ] No [ ] serve? Yes [ ] No [x ] Location where Summary Report required under O. Reg. 170/03 Schedule 22 will be Number of Interested Authorities you available for inspection. report to: N/A Bayham Wastewater Treatment Plant Did you provide a copy of your annual 1 Chatham St. report to all Interested Authorities you Port Burwell,ON 519-874-4761 report to for each Designated Facility? Yes [ ] No [ x ] Note: For the following tables below, additional rows or columns may be added or an appendix may be attached to the report List all Drinking-Water Systems (if any), which receive all of their drinking water from oursystem: Drinking Water System Name Drinking Water System Number N/A Did you provide a copy of your annual report to all Drinking-Water System owners that are connected to you and to whom you provide all of its drinking water? Yes [ ] No [ ] Drinking Water Systems Regulations Page 1 of 6 (PIBS 4435e01)February 2008 rr� (ir Ontario Drinking-Water Systems Regulation O. Reg. 170/03 Indicate how you notified system users that your annual report is available, and is free of charge. [x] Public access/notice via the web [x ] Public access/notice via Government Office [ ] Public access/notice via a newspaper [x] Public access/notice via Public Request [ ] Public access/notice via a Public Library [x] Public access/notice via other method --- water bills Describe your Drinking-Water System The community is serviced by two drilled overburden wells and treatment equipment upgrades including raw water softeners, nitrate filters, pre and post chlorination, post filtration, uv disinfection, on-line continuous monitoring equipment including nitrate, turbidity and chlorine. The system is monitored and alarmed by a computerized SCADA system. List all water treatment chemicals used over this reporting eriod Sodium Hypochlorite ( 12% ) Were any significant expenses incurred to? [x] Install required equipment [ x ] Repair required equipment [ x ] Replace required equipment Please provide a brief description and a breakdown of monetary expenses incurred - Hydrant flushing - Valve turning - Flow meter calibrations - Operating: $106,234 Drinking Water Systems Regulations Page 2 of 6 (PIBS 4435e01)February 2008 rr� (ir Ontario Drinking-Water Systems Regulation O. Reg. 170/03 Provide details on the notices submitted in accordance with subsection 18(1) of the Safe Drinking-Water Act or section 16-4 of Schedule 16 of O.Reg.170/03 and reported to Spills Action Centre Incident Parameter Result Unit of Corrective Action Corrective Date Measure Action Date Jan.15/24 Sodium 28.1 mg/L Ongoing DWA Jan 29/24 by MOH Microbiological testing done under the Schedule 10, 11 or 12 of Regulation 170/03, during this rep rting period. Number Range of E.Coli Range of Total Number Range of HPC of Or Fecal Coliform of HPC Results Samples Results Results Samples (min#)-(max#) (min#)-(max#) (min#)-(max#) Raw 24 0 0-0 0 Treated Distribution 108 0 0 - 0 108 >10 - 40 Operational testing done under Schedule 7, 8 or 9 of Regulation 170/03 during the period covered by this Annual Report. Number of Range of Results Grab (min#)-(max#) NOTE: For continuous Samples monitors use 8760 as the Turbidity 8760 0.00—2.00 (equip number of samples. cal Chlorine 8760 0.00—3.76(equip. cal) (free Fluoride(If the DWS provides NOTE: Record the unit of measure if it is not milligrams per litre. Summary of additional testing and sampling carried out in accordance with the requirement of an approval, order or other legal instrument. Date of legal instrument Parameter Date Sampled Result Unit of Measure issued Drinking Water Systems Regulations Page 3 of 6 (PIBS 4435e01)February 2008 r� Vr Ontario Drinking-Water Systems Regulation O. Reg. 170/03 Summary of Inorganic parameters tested during this reporting period or the most recent sample results Parameter Sample Date Result Value Unit of Measure Exceedance Antimony Jan. 6/2025 0.6 <MDL /L Arsenic Jan. 6/2025 0.2 <MDL /L Barium Jan. 6/2025 35.2 kt /L Boron Jan. 6/2025 24 /L Cadmium Jan. 6/2025 0.008 /L Chromium Jan. 6/2025 0.08 <MDL /L *Lead See below Mercury Jan. 6/2025 0.01 <MDL /L Selenium Jan. 6/2025 0.04<MDL /L Sodium Jan.15/24 28.1 m /L Yes- DWA Uranium Jan. 6/2025 0.028 /L Fluoride Jan. 6/2025 0.11 m /L Nitrite Annual range 0.003-0.004 m /L Nitrate Annual range 3.21 —8.95 m /L *only for drinking water systems testing under Schedule 15.2; this includes large municipal non- residential systems, small municipal non-residential systems,non-municipal seasonal residential systems, large non-municipal non-residential systems, and small non-municipal non-residential systems Summary of lead testing under Schedule 15.1 during this reporting period (applicable to the following drinking water systems; large municipal residential systems, small municipal residential systems, and non-municipal year-round residential systems) Range of Lead Location Type Number of Results Number of Samples min# — max# Exceedances Plumbing 0 Distribution 4 Alk. =279—299 mg/L 0 pH= 7.17-7.54 Summary of Organic parameters sampled during this reporting period or the most recent sample results Drinking Water Systems Regulations Page 4 of 6 (PIBS 4435e01)February 2008 r� Vr OntariO Drinking-Water Systems Regulation O. Reg. 170103 Parameter Sample Result Value Unit Exceedance Date of Measu re Alachlor Jan.6/2025 0.02 <MDL /L Atrazine Jan.6/2025 0.01 <MDL /L Atrazine+N-dealkylated metobolites Jan.6/2025 0.01 <MDL /L Azinphos-methyl Jan.6/2025 0.05 <MDL /L Benzene Jan.6/2025 0.32 <MDL /L, Benzo(a)pyrene Jan.6/2025 0.004 µg/L <MDL Bromoxynil Jan.6/2025 0.33 <MDL /L Carbaryl Jan.6/2025 0.05 <MDL /L Carbofuran Jan.6/2025 0.01 <MDL /L Carbon Tetrachloride Jan.6/2025 0.17<MDL /L Chlorpyrifos Jan.6/2025 0.02 <MDL /L Desethyl Atrrazine Jan.6/2025 0.01 /L Diazinon Jan.6/2025 0.02 <MDL /L Dicamba Jan.6/2025 0.20 <MDL /L 1,2-Dichlorobenzene Jan.6/2025 0.41 <MDL /L 1,4-Dichlorobenzene Jan.6/2025 0.36 <MDL /L 1,2-Dichloroethane Jan.6/2025 0.35 <MDL /L 1,1-Dichloroethylene Jan.6/2025 0.33 <MDL µg/L vin lidene chloride Dichloromethane Jan.6/2025 0.35 <MDL /L 2-4 Dichlorophenol Jan.6/2025 0.15 <MDL /L 2,4-Dichlorophenoxy acetic acid(2,4-D) Jan.6/2025 0.19 <MDL /L Diclofop-methyl Jan.6/2025 0.40 <MDL /L Dimethoate Jan.6/2025 0.06<MDL /L Diquat Jan.6/2025 1 <MDL /L Diuron Jan.6/2025 0.03 <MDL /L Glyphosate Jan.6/2025 1 <MDL /L Malathion Jan.6/2025 0.02 <MDL /L MCPA Jan.6/2025 0.00012 µg/L <MDL Metolachlor Jan.6/2025 0.01 <MDL /L Metribuzin Jan.6/2025 0.02 <MDL /L Monochlorobenzene Jan.6/2025 0.3 <MDL /L Paraquat Jan.6/2025 1 <MDL /L Pentachlorophenol Jan.6/2025 0.15 <MDL /L. Phorate Jan.6/2025 0.01 <MDL /L Picloram Jan.6/2025 1 <MDL /L Polychlorinated Biphenyls(PCB) Jan.6/2025 0.04 <MDL /L Prometryne Jan.6/2025 0.03 <MDL /L Simazine Jan.6/2025 0.01 <MDL /L Drinking Water Systems Regulations Page 5 of 6 (PIBS 4435e01)February 2008 rr� (ir Ontario Drinking-Water Systems Regulation O. Reg. 170/03 THM 2025 8.6 µg/L (NOTE: show latest annual average) Terbufos Jan.6/2025 0.01 <MDL /L Tetrachloroethylene Jan.6/2025 0.35 <MDL /L 2,3,4,6-Tetrachlorophenol Jan.6/2025 0.20 <MDL /L Triallate Jan.6/2025 0.01 <MDL /L Trichloroethylene Jan.6/2025 0.44 <MDL /L 2,4,6-Trichlorophenol Jan.6/2025 0.25 <MDL /L Trifluralin Jan.6/2025 0.02 <MDL /L Vinyl Chloride Jan.6/2025 0.17<MDL /L HAAs(Total Haloacetic Acids) 2025 5.3 <MDL µg/L (NOTE: show latest annual average) List any Inorganic or Organic parameter(s) that exceeded half the standard prescribed in Schedule 2 of Ontario Drinking Water Quality Standards. Parameter Result Value Unit of Measure Date of Sample Drinking Water Systems Regulations Page 6 of 6 (PIBS 4435e01)February 2008