Loading...
HomeMy WebLinkAboutJanuary 05, 2023 - CouncilTHE CORPORATION OF THE MUNICIPALITY OF BAYHAM COUNCIL MEETING AGENDA MUNICIPAL OFFICE 56169 Heritage Line, Straffordville, ON Council Chambers – HYBRID Thursday, January 5, 2023 7:00 p.m. The January 5, 2023 Council Meeting will allow for a hybrid meeting function – you may attend in person or virtually through the live-stream on the Municipality of Bayham’s YouTube Channel: https://www.youtube.com/channel/UCpY8wjivr1zSsi0tvbgtUrg 1. CALL TO ORDER 2. DISCLOSURES OF PECUNIARY INTEREST & THE GENERAL NATURE THEREOF 3. REVIEW OF ITEMS NOT LISTED ON AGENDA 4. ANNOUNCEMENTS 5. PRESENTATIONS 6. DELEGATIONS 7. ADOPTION OF MINUTES OF PREVIOUS MEETING(S) A. Special Council Meeting held December 13, 2022 B. Regular Council Meeting held December 15, 2022 C. Statutory Planning Meeting held December 15, 2022 8. MOTIONS AND NOTICE OF MOTION 9. OPEN FORUM 10. RECREATION, CULTURE, TOURISM AND ECONOMIC DEVELOPMENT 10.1 Correspondence 10.1.1 Receive for Information 10.1.2 Requiring Action 10.2 Reports to Council 11. PHYSICAL SERVICES – EMERGENCY SERVICES 11.1 Correspondence 11.1.1 Receive for Information 11.1.2 Requiring Action 11.2 Reports to Council 2023 Council Agenda January 5, 2023 2 A. Report PS-01/23 by Ed Roloson, Water/Wastewater Operations re RFT-22-02 One (1) New Half-Ton Four Wheel Drive Pickup Truck B. Report FR-01/23 by Harry Baranik, Fire Chief & Ed Roloson, Water/Wastewater Operations re Capital Item No. FD-02 – Water Flow Survey 12. DEVELOPMENT SERVICES – SUSTAINABILITY AND CONSERVATION 12.1 Correspondence 12.1.1 Receive for Information A. Notice of the Passing of Zoning By-law Amendment ZBA-04/22 – Vienna Farms Ltd. B. Notice of the Passing of Zoning By-law Amendment ZBA-03/22 – Bonnefield C. Notice of Public Meeting for a Proposed Zoning By-law Amendment – Latimer 12.1.2 Requiring Action 12.2 Reports to Council A. Report DS-01/23 by Margaret Underhill, Deputy Clerk|Planning Coordinator re Draft Plan of Subdivision Application – 34T-BY202201, 11:28 Properties Inc. Eden B. Report DS-02/23 by Thomas Thayer, CAO|Clerk re Building Services 4th Quarter Report 13. FINANCE AND ADMINISTRATION 13.1 Correspondence 13.1.1 Receive for Information A. Town of Newmarket re Bill 23, More Homes Built Faster Act, 2022 B. Town of West Lincoln re Bill 23, More Homes Built Faster Act, 2022 C. City of Cambridge re Bill 23, More Homes Built Faster Act, 2022 D. Municipality of North Perth re Bill 23, More Homes Built Faster Act, 2022 E. Municipality of Tweed re Natural Gas F. County of Elgin re December 2022 Economic Development Newsletter G. LPRCA re Response to 2023 Draft Budget Correspondence 13.1.2 Requiring Action A. Desi Broughton re Port Burwell Ice Rink 13.2 Reports to Council A. Report CAO-02/23 by Thomas Thayer, CAO|Clerk re Port Burwell Lighthouse Heritage and Structural Assessment 2023 Council Agenda January 5, 2023 3 14. BY-LAWS 15. UNFINISHED BUSINESS 16. OTHER BUSINESS 16.1 In Camera A. Confidential Report re Labour relations, employee negotiations (Shared Services) 16.2 Out of Camera 17. BY-LAW TO CONFIRM THE PROCEEDINGS OF COUNCIL A. By-law No. 2023-001 Being a by-law to confirm all actions of Council 18. ADJOURNMENT THE CORPORATION OF THE MUNICIPALITY OF BAYHAM SPECIAL COUNCIL MEETING MINUTES MUNICIPAL OFFICE 56169 Heritage Line, Straffordville, ON Council Chambers - HYBRID Tuesday, December 13, 2022 6:30 p.m. The December 13, 2022 Council Meeting was held using hybrid technologies via Zoom and livestreamed on YouTube. PRESENT: MAYOR ED KETCHABAW DEPUTY MAYOR RAINEY WEISLER COUNCILLORS TIMOTHY EMERSON DAN FROESE *attended via Zoom SUSAN CHILCOTT STAFF PRESENT: CAO|CLERK THOMAS THAYER DEPUTY CLERK MEAGAN ELLIOTT TREASURER LORNE JAMES MANAGER OF PUBLIC WORKS|DRAINAGE SUPERINTENDENT STEVE ADAMS MANAGER OF CAPITAL PROJECTS| WATER/WASTEWATER ED ROLOSON 1. CALL TO ORDER Mayor Ketchabaw called the meeting to order at 6:30 p.m. 2. DISCLOSURES OF PECUNIARY INTEREST & THE GENERAL NATURE THEREOF No disclosures of pecuniary interest were declared. 3. 2023 – 2032 CAPITAL BUDGET - DRAFT A. Report TR-18/22 by Lorne James, Treasurer re 2023-2032 Capital Budget – Draft Council recessed at 7:32 p.m. for a short break and returned at 7:42 p.m. Moved by: Councillor Chilcott Seconded by: Councillor Emerson THAT Report TR-18/22 re 2023-2032 Capital Budget - Draft be received for information; AND THAT staff bring forward a report regarding strategies to fund beach accessibility improvements; 2022 Council Minutes December 13, 2022 AND THAT the 2023-2032 Capital Budget – Draft be amended as discussed and approved in principle. CARRIED 4. BY-LAW A. By-law No. 2022-083 Being a by-law to confirm all actions of Council Moved by: Deputy Mayor Weisler Seconded by: Councillor Chilcott THAT Confirming By-law No. 2022-083 be read a first, second and third time and finally passed. CARRIED 5. ADJOURNMENT Moved by: Councillor Froese Seconded by: Councillor Chilcott THAT the Council meeting be adjourned at 8:12 p.m. CARRIED MAYOR CLERK THE CORPORATION OF THE MUNICIPALITY OF BAYHAM COUNCIL MEETING MINUTES MUNICIPAL OFFICE 56169 Heritage Line, Straffordville, ON Council Chambers – HYBRID Thursday, December 15, 2022 7:00 p.m. 7:30 p.m. Planning Public Meeting – 2 Applications The December 15, 2022 Council Meeting was held using hybrid technologies via Zoom and livestreamed on YouTube. PRESENT: MAYOR ED KETCHABAW DEPUTY MAYOR RAINEY WEISLER COUNCILLORS TIMOTHY EMERSON DAN FROESE SUSAN CHILCOTT STAFF PRESENT: CAO|CLERK THOMAS THAYER DEPUTY CLERK MEAGAN ELLIOTT DEPUTY CLERK|PLANNING COORDINATOR MARGARET UNDERHILL MANAGER OF CAPITAL PROJECTS| WATER/WASTEWATER ED ROLOSON FIRE CHIEF|BYLAW ENFORCEMENT OFFICER HARRY BARANIK 1. CALL TO ORDER Mayor Ketchabaw called the meeting to order at 7:00 p.m. 2. DISCLOSURES OF PECUNIARY INTEREST & THE GENERAL NATURE THEREOF No disclosures of pecuniary interest were declared. 3. REVIEW OF ITEMS NOT LISTED ON AGENDA 12.2 B Report DS-61/22 by Margaret Underhill, Deputy Clerk|Planning Coordinator re Zoning By-law Amendment ZBA-04/22 Vienna Farms Ltd. 4964 and 4968 Plank Road 12.2 C Report DS-62/22 by Margaret Underhill, Deputy Clerk|Planning Coordinator re Zoning By-law Amendment ZBA-03/22 Bonnefield Canadian Farmland LP III, 56237 Chute Line 14. G By-law No. Z752-2022 Being a by-law to amend By-law No. Z456-2003, as amended – Vienna Farms 14. H By-law No. Z753-2022 Being a by-law to amend By-law No. Z456-2003, as amended – Bonnefield 2022 Council Minutes December 15, 2022 2 4. ANNOUNCEMENTS The CAO|Clerk reminded residents of the Christmas office closure, from noon on December 23, 2022 until 8:30 am on January 3, 2023 and noted that bag tags are available for pick-up prior to the Christmas office closure. The CAO|Clerk advised that the 2023-24 Operating Budget Draft is available on the website and will be considered by Council at a Special Meeting on Wednesday, January 18, 2023, commencing at 6:30 pm. Mayor Ed Ketchabaw informed that on Wednesday, December 14, 2022, Bayham participated in a joint emergency exercise and reviewed the Emergency Response Plan (ERP) with other Elgin County municipalities, including Elgin County. The exercise is an annual condition of compliant with Emergency Management Ontario. Mayor Ed Ketchabaw advised that, on Sunday, December 18, 2022, there will be breakfast at the Masonic Hall from 8-1. The Mayor also wished all those a safe and happy Christmas and a relaxing festive time before we return in the New Year. 5. PRESENTATIONS 6. DELEGATIONS 7. ADOPTION OF MINUTES OF PREVIOUS MEETING(S) A. Regular Council Meeting held December 1, 2022 Moved by: Deputy Mayor Weisler Seconded by: Councillor Emerson THAT the minutes from the December 1, 2022 Regular Meeting of Council be approved as presented. CARRIED 8. MOTIONS AND NOTICE OF MOTION A. Councillor Chilcott re Province-wide Shortage of Children’s Medication Moved by: Councillor Chilcott Seconded by: Councillor Froese WHEREAS staffing shortages of healthcare professionals, especially nurses, is an ongoing problem in Ontario; AND WHEREAS this problem continues to grow since the COVID-19 Pandemic and the passing of Bill 124, a Bill which suppresses the wages of nurses and health-care professionals and limits their ability to negotiate freely; AND WHEREAS these staffing shortages are causing substantial wait times in emergency 2022 Council Minutes December 15, 2022 3 rooms, noticeably widening gaps in health care, and emergency room closures; AND WHEREAS there has been an increase in child sicknesses contributed by a lack of timely and available health care; AND WHEREAS there is a province-wide shortage in children and medications, both over-the counter and prescribed; NOW THEREFORE BE IT RESOLVED THAT the Municipality of Bayham calls on the Ontario government to recognize and address the deepening health care crisis in Ontario and take urgent action to remedy human resources and medication shortages to properly serve Ontario residents; AND THAT a copy of this Resolution be sent to: • The Premier of Ontario and the Ontario Minister of Health; • The Leader of the Official Opposition and the Opposition Critic for Health; • All Members of Provincial Parliament representing constituencies in Bayham; and, • The Association of Municipalities of Ontario (AMO), requesting they share with their member municipalities. CARRIED 9. OPEN FORUM 10. RECREATION, CULTURE, TOURISM AND ECONOMIC DEVELOPMENT 10.1 Correspondence 10.1.1 Receive for Information 10.1.2 Requiring Action 10.2 Reports to Council 11. PHYSICAL SERVICES – EMERGENCY SERVICES 11.1 Correspondence 11.1.1 Receive for Information 11.1.2 Requiring Action 11.2 Reports to Council A. Report PS-24/22 by Ed Roloson, Water/Wastewater Operations re Drinking Water Quality Management Standards Moved by: Councillor Froese Seconded by: Councillor Chilcott THAT Staff Report PS-24/22 re Drinking Water Quality Management Standards be received for information; 2022 Council Minutes December 15, 2022 4 AND THAT the Council of the Corporation of the Municipality of Bayham endorse both the Bayham Water Distribution System and the Richmond Community Water System Operational Plans; AND THAT the Bayham Water Distribution System and the Richmond Community Water System Operational Plans be reviewed annually by staff and revisions made as necessary to maintain and improve the quality management system. CARRIED 12. DEVELOPMENT SERVICES – SUSTAINABILITY AND CONSERVATION 12.1 Correspondence 12.1.1 Receive for Information A. Notice of Public Meeting re Proposed Revised Official Plan and Zoning By-Law Amendment – M & R Glen C/O Barry Wade Homes Inc. B. Notice of Public Meeting re Proposed Draft Plan of Subdivision Application – Vienna Ridge 34T-BA2201 Moved by: Deputy Mayor Weisler Seconded by: Councillor Chilcott THAT items 12.1.1 A & B be received for information. CARRIED 12.1.2 Requiring Action 12.2 Reports to Council A. Report DS-63/22 by Margaret Underhill, Deputy Clerk|Planning Coordinator re Bill 109, More Homes for Everyone Act, 2022 Moved by: Deputy Mayor Weisler Seconded by: Councillor Chilcott THAT Report DS-63/22 regarding Bill 109, the More Homes for Everyone Act, 2022, be received for information; AND THAT in consideration of the IBI Group Memorandum, dated December 8, 2022, Council directs staff to continue the review for the next several months to further deliberate on actions to improve the Municipality’s land use planning policies, procedures and by-laws in response to the new legislation. CARRIED B. Report DS-61/22 by Margaret Underhill, Deputy Clerk|Planning Coordinator re Zoning By-law Amendment ZBA-04/22 Vienna Farms Ltd. 4964 and 4968 Plank Road Moved by: Councillor Froese 2022 Council Minutes December 15, 2022 5 Seconded by: Councillor Emerson THAT Report DS-61/22 regarding the Vienna Farms Ltd. rezoning application ZBA-04/22 be received for information; AND THAT Zoning By-law No. Z456-2003, as amended, be further amended by changing the zoning on the subject lands from Agricultural (A1) to a site-specific Agricultural (A1-43) Zone; AND THAT Zoning By-law No. Z752-2022 be presented to Council for enactment. CARRIED C. Report DS-62/22 by Margaret Underhill, Deputy Clerk|Planning Coordinator re Zoning By-law Amendment ZBA-03/22 Bonnefield Canadian Farmland LP III, 56237 Chute Line Moved by: Deputy Mayor Weisler Seconded by: Councillor Chilcott THAT Report DS-62/22 regarding the Bonnefield Canadian Farmland LP III rezoning application ZBA-03/22 be received for information; AND THAT Zoning By-law No. Z456-2003, as amended, be further amended by changing the zoning on the subject lands from Agricultural (A1) to a site-specific Agricultural (A1-A- 44) Zone; AND THAT Zoning By-law No. Z753-2022 be presented to Council for enactment. CARRIED The Council Meeting recessed to host a Statutory Planning Public Meeting at 7:30 p.m. The Council Meeting resumed at 8:44 p.m. 13. FINANCE AND ADMINISTRATION 13.1 Correspondence 13.1.1 Receive for Information A. Town of Petrolia re Strengthening Powers of the Integrity Commissioner B. Town of Orangeville re Bill 23 C. City of Toronto re Update on Bill 23 D. Ministry of Natural Resources re Changes under the Oil, Gas and Salt Resources Act E. Long Point Region Conservation Authority re November 2, 2022 Minutes F. Long Point Region Conservation Authority re November 9, 2022 Minutes 2022 Council Minutes December 15, 2022 6 G. Port Burwell Historical Society re Museums Bayham Board Reactivation Petition H. County of Elgin re Ed Ketchabaw Elected as Elgin County Warden Moved by: Councillor Emerson Seconded by: Councillor Froese THAT items 13.1.1A-H be received for information; AND THAT the information contained in item 13.1.1G be considered during the discussion of Report CL-10/22. CARRIED 13.1.2 Requiring Action A. Elgin County Police Services Board re Malahide Appointment Moved by: Councillor Emerson Seconded by: Councillor Chilcott THAT the Council of the Municipality of Bayham supports the appointment of Dominique Giguere as the Elgin Group Police Services Board elected representative from Eastern Elgin for a three (3) year term ending December 31, 2025 or until such time that the Ministry approves the new Board composition under the Community Safety and Policing Act (CPSA), 2022, whichever is earlier. CARRIED 13.2 Reports to Council A. Report CL-10/22 by Meagan Elliott, Deputy Clerk re 2022-2026 Committees of Council and Council Appointments Moved by: Councillor Froese Seconded by: Councillor Emerson THAT Report CL-10/22 re 2022-2026 Committees of Council and Council Appointments be received for information; AND THAT the Council of The Corporation of the Municipality of Bayham make the following appointments:  The Council of the Corporation of the Municipality of Bayham be appointed as the Committee of Adjustment;  The Council of the Corporation of the Municipality of Bayham be appointed as the Court of Revision;  Rainey Weisler be appointed to the Long Point Region Conservation Authority Board of Directors;  Tim Emerson (alternate) be appointed to Elgin Area Primary Water Supply System Board;  Tim Emerson (primary) & Rainey Weisler (alternate) be appointed to Port Burwell Secondary Water Supply System Board; and, 2022 Council Minutes December 15, 2022 7  Ed Ketchabaw, Susan Chilcott & Dan Froese be appointed to the Joint Otter Valley Utility Corridor Board of Management. AND THAT staff report back to Council with terms of reference to establish the following Advisory Committees of Council for the 2022-2026 term:  Waterfront Advisory Committee  Museums Bayham Committee  Joint Cemetery Board CARRIED B. Report CAO-69/22 by Thomas Thayer, CAO|Clerk re 2023 Insurance Renewal Moved by: Deputy Mayor Weisler Seconded by: Councillor Chilcott THAT Report CAO-69/22 re 2023 Insurance Renewal be received for information; AND THAT the 2023 Municipal Insurance Program be obtained from Marsh Canada Limited in accordance with the offer to renew dated November 30, 2022, at a total premium of $203,681 plus applicable taxes. AND THAT staff be directed issue a Municipal Insurance Program Request for Proposals (RFP) process in 2023 for the 2024 Municipal Insurance Program CARRIED C. Report CAO-70/22 by Thomas Thayer, CAO|Clerk re Agreement for Building Services Support – Hillenaar – Six (6) Month Contract Moved by: Councillor Chilcott Seconded by: Deputy Mayor Weisler THAT Report CAO-70/22 re Agreement for Building Services Support – Hillenaar – Six (6)-Month Contract be received for information; AND THAT Council enter into an Agreement between the Municipality of Bayham and Hillenaar Consulting Inc. for the provision of building services for the Municipality of Bayham; AND THAT the appropriate by-laws to enter into an Agreement for Building Services and to appoint a Deputy Chief Building Official be brought forward for Council’s consideration. CARRIED 14. BY-LAWS A. By-Law No. 2022-076 Being a by-law to provide for an interim tax levy 2022 Council Minutes December 15, 2022 8 B. By-Law No. 2022-077 Being a by-law to authorize borrowing from time to time to meet current expenditures during the fiscal year ending December 31, 2023 C. By-Law No. 2022-078 Being a by-law to appoint a by-law enforcement and property standard officers and to execute an agreement with Tenet Security Group Inc. for these services within the Municipality of Bayham D. By-Law No. 2022-079 Being a by-law to authorize the execution of an agreement between the Municipality of Bayham and Ramona Peidl for provision of recycling receptacle services E. By-Law No. 2022-080 Being a by-law to amend by-law 2022-011 being a by-law to appoint municipal officers and employees for the Municipality of Bayham F. By-Law No. 2022-081 Being a by-law to authorize the execution of an agreement between the Corporation of the Municipality of Bayham and Hillenaar Consulting Inc. G. By-law No. Z752-2022 Being a by-law to amend By-law No. Z456-2003, as amended – Vienna Farms H. By-law No. Z753-2022 Being a by-law to amend By-law No. Z456-2003, as amended – Bonnefield Moved by: Councillor Chilcott Seconded by: Councillor Froese THAT By-law Nos. 2022-076, 2022-077, 2022-078, 2022-079, 2022-080, 2022-081, Z752- 2022 and Z753-2022 be read a first, second and third time and finally passed. CARRIED 15. UNFINISHED BUSINESS 16. OTHER BUSINESS 16.1 In Camera Moved by: Councillor Chilcott Seconded by: Deputy Mayor Weisler THAT the Council do now rise to enter into an “In Camera” Session at 9:37 p.m. to discuss: A. Confidential Report re Personal matters about an identifiable individual (Committee Appointment) CARRIED 16.2 Out of Camera Moved by: Councillor Froese Seconded by: Councillor Chilcott 2022 Council Minutes December 15, 2022 9 THAT the Council do now rise from the “In Camera” session at 9:45 p.m. and report on Confidential Report re Personal matters about an identifiable individual (Committee Appointment) CARRIED Moved by: Deputy Mayor Weisler Seconded by: Councillor Chilcott THAT Confidential Report CAO-66/22 re Personal matters about an identifiable individual (Committee Appointment) be received for information; AND THAT John Seldon be recommended to Elgin County as Bayham’s Land Division Committee appointee for the 2022-2026 term. CARRIED 17. BY-LAW TO CONFIRM THE PROCEEDINGS OF COUNCIL A. By-law No. 2022-082 Being a by-law to confirm all actions of Council Moved by: Deputy Mayor Weisler Seconded by: Councillor Chilcott THAT Confirming By-law No. 2022-082 be read a first, second and third time and finally passed. CARRIED 18. ADJOURNMENT Moved by: Councillor Froese Seconded by: Councillor Chilcott THAT the Council meeting be adjourned at 9:47 p.m. CARRIED MAYOR CLERK THE CORPORATION OF THE MUNICIPALITY OF BAYHAM STATUTORY PLANNING MEETING MINUTES MUNICIPAL OFFICE 56169 Heritage Line, Straffordville, ON Council Chambers – HYBRID Thursday, December 15, 2022 7:30 p.m. A. Vienna Ridge Subdivision 34T-BA2201 B. Proposed Official Plan Amendment OPA-01/22 and Zoning By-Law Amendment ZBA-02/22 – Michael and Reta Glen C/O Barry Wade Homes Inc. The December 15, 2022 Statutory Planning Meeting was held using hybrid technologies via Zoom and livestreamed on YouTube. PRESENT: MAYOR ED KETCHABAW DEPUTY MAYOR RAINEY WEISLER COUNCILLORS TIMOTHY EMERSON DAN FROESE SUSAN CHILCOTT STAFF PRESENT: CAO|CLERK THOMAS THAYER DEPUTY CLERK MEAGAN ELLIOTT DEPUTY CLERK|PLANNING COORDINATOR MARGARET UNDERHILL MANAGER OF CAPITAL PROJECTS| WATER/WASTEWATER ED ROLOSON FIRE CHIEF|BYLAW ENFORCEMENT OFFICER HARRY BARANIK PUBLIC ATTENDEES A: MUIREANN PETERS JOHN NEZEZON TREVOR BENJAMINS – CJDL HANK REDECOP JAKE REDECOP PUBLIC ATTENDEES B: VALERIE DONNELL DOUG PARK BARRY WADE SUSANNE SCHLOTZHAUER LAVERNE KIRKNESS DON JESSO KIM KIMBARK ANNA & MANNY MATOS DAWN MASSIAH LEANNE UTTING HILARY UTTING KEN YOUNG C G TUFFIN 2 Statutory Planning Minutes December 15, 2022 APPLICATION A - Vienna Ridge Subdivision 34T-BA2201 1. CALL TO ORDER Mayor Ketchabaw called the meeting to order at 7:30 p.m. 2. DISCLOSURES OF PECUNIARY INTEREST & THE GENERAL NATURE THEREOF No disclosures of pecuniary interest were declared. 3. CHAIRMAN’S REMARKS ON THE PURPOSE OF THE MEETING The Chairman stated the purpose and effect of the proposed amendment. 4. PURPOSE AND EFFECT OF THE PROPOSED AMENDMENT A. Vienna Ridge Subdivision 34T-BA2201 THE PURPOSE OF THIS MEETING is to inform the public of the nature of the Draft Plan of Subdivision proposal, to invite public input and to answer questions regarding the application. THE PURPOSE AND EFFECT of this Draft Plan of Subdivision will be to divide the subject parcel of land into eight (8) single detached residential lots. The proposed lots will be accessed by North Street, an existing local road, south of Chapel Street. The residential lots will be serviced by municipal sanitary sewage disposal system, municipal water services and municipal storm water services. The subject lands are designated ‘Residential’ in the Municipality of Bayham Official Plan and are zoned Holding Village Residential 1 (R1(h2)) in the Municipality of Bayham Zoning By-law No. Z456-2003. The applicants will be required to apply for and obtain Zoning By-law Amendment approval to remove the Holding Provision (h2) subject to entering into subdivision agreement between the applicant and the Municipality. 5. PUBLIC PARTICIPATION Trevor Benjamins, consulting engineer with CJDL, spoke to the application and addressed comments with concerns surrounding water, sanitary sewer and drainage. Muireann Peters, resident, asked clarifying questions on the current use of the land and future road works. 6. CORRESPONDENCE Public Comments Received by December 8, 2022: Application “A” Vienna Ridge Subdivision – 2 items  John Nezezon, November 25, 2022 email  George Nebenzahl, December 6, 2022 email 3 Statutory Planning Minutes December 15, 2022 7. OTHER BUSINESS No other business. 8. ADJOURNMENT Moved by: Deputy Mayor Weisler Seconded by: Councillor Chilcott THAT the Zoning By-law amendment be considered following the approval of a Plan of Subdivision Agreement; AND THAT pursuant to the Planning Act requirements, the Public Meeting for Draft Plan of Subdivision File No. 34T-BA2201, Vienna Ridge, is now complete at 7:39 p.m. CARRIED APPLICATION B - Proposed Official Plan Amendment OPA-01/22 and Zoning By-Law Amendment ZBA-02/22 – Michael and Reta Glen C/O Barry Wade Homes Inc. 9. CALL TO ORDER Mayor Ketchabaw called the meeting to order at 7:39 p.m. 10. DISCLOSURES OF PECUNIARY INTEREST & THE GENERAL NATURE THEREOF No disclosures of pecuniary interest were declared. 11. CHAIRMAN’S REMARKS ON THE PURPOSE OF THE MEETING The Chairman stated the purpose and effect of the proposed amendment. 12. PURPOSE AND EFFECT OF THE PROPOSED AMENDMENT B. Proposed Zoning By-Law Amendment ZBA-02/22 and Official Plan Amendment OPA-01/22 – Michael and Reta Glen C/O Barry Wade Homes Inc. THE PURPOSE of these Amendments is to change the land use designation on a portion of lands with two parcels and combined lot area of 3,604 m2 (0.89 acre), to change the Official Plan designation for 2,760 m2 (0.68 acres) of lands from “Residential” to “site-specific Multi-Unit Residential” designation in the Official Plan of the Municipality of Bayham to permit the development of a 13-unit townhouse block with density of 48 units per hectare and criteria for slope development on the southern portion of the subject lands. The subject lands are located on the east side of Robinson Street, west side of Erieus Street, south of Brock Street in the village of Port Burwell and known as 2 Robinson Street and 3 Erieus Street. And furthermore, to change the zoning of the townhouse block lands from Village Residential 1 (R1) and Holding Village Residential 1 (R1(h2)) Zones to Site-specific Village Residential 2 (R2- xx) Zone to permit townhouse development and to permit specific to the townhouse lands: lot 4 Statutory Planning Minutes December 15, 2022 area per unit of 212 m2 whereas 340 m2 is the permitted minimum; setback distance for a driveway to a street intersection of 1.0 m whereas 9.0 m is the permitted minimum; front yard setback of 2.02 m whereas 6.0 m is the permitted minimum; and, to remove the ‘h2’ holding symbol by way of entering into a development agreement with the municipality, in Zoning By-law Z456-2003. THE EFFECT of these Amendments will be to permit a townhouse development with site- specific zoning, either standard condominium or rental, in the form of 2 buildings with 13 total units, proposed with reduced driveway setback from an intersection, reduced front yard setback, and the removal of holding provisions requiring the applicant/owner enter into development or subdivision agreement with the municipality. 13. PUBLIC PARTICIPATION Laverne Kirkness, planning consultant for the applicant, presented a slideshow outlining the revised plan including the removal of Block A to eliminate shadowing concerns, the height of the buildings will not obstruct existing homes views, the lands are not in a flood hazard, there will be no short-term rentals and construction will be only on their lands and will not use municipal property. Doug Park, resident, spoke in support of the application for economic development. Don Jesso, resident, spoke in support of the application for economic development. Hilary Utting, resident, spoke in opposition of the application. Utting provided background information of the lands and wildlife that has been present over the years. Utting noted concerns with traffic, driveway location, removing the retainer wall, the amount of ground water that nearby residents with basements have issues with and the risk of Port Burwell losing its charm. Christina Tuffin, resident, spoke in opposition of the application. Tuffin noted concerns with traffic, use of the buildings, and the risk of Port Burwell losing its charm. Tuffin noted being in support of development but the right kind in the right location. Ken Young, resident, spoke in support of the application for increasing Bayham’s tax base. Valerie Donnell, resident, spoke in opposition of the application. Donnell noted concerns with the risk of Port Burwell losing its charm and questioned how it would increase economic development. 14. CORRESPONDENCE Public Comments Received by December 8, 2022: Application “B” OPA-01/22 and ZBA-02/22 – 16 items  Anna Chibueze, November 25, 2022 email  Nancy and Rick (Bodsworth) Hannah, November 28, 2022 email  Symen and Faye Salverda, November 30, 2022 email  Frank A. de Swart, December 1, 2022 email  John Wylie, December 2, 2022 correspondence via email 5 Statutory Planning Minutes December 15, 2022  Kim and Michele Kimbark, December 4, 2022 correspondence via email  Carolyn Baker, December 4, 2022 correspondence via email  Nancy Windsor, December 5, 2022 correspondence  Rod Littleton, December 5, 2022 email  Jordy Robinson, December 5, 2022 email  Scott and Laurie Baker, December 5, 2022 email  Christina Tuffin-Crumb and James Crumb, December 6, 2022 correspondence  Marni Wolfe, December 6, 2022 email  Cindy Stewart, December 6, 2022 email  David Robinson, December 6, 2022 email  Dan Seeley-Baechler, December 6, 2022 correspondence via email Correspondence received after posting the agenda:  Wendy Carmichael, December 14, 2022 email – circulated to Council December 15, 2022 M. Underhill read aloud the correspondence received from Wendy Carmichael. 15. OTHER BUSINESS No other business. 16. ADJOURNMENT Moved by: Councillor Froese Seconded by: Councillor Chilcott THAT the Official Plan Amendment and Zoning By-law amendment be considered at a future meeting of Council; AND THAT pursuant to the Planning Act requirements, the Public Meeting for the revised application of Official Plan Amendment OPA-01/22 and Zoning By-Law Amendment ZBA-02/22 is now complete at 8:30 p.m. CARRIED MAYOR CLERK REPORT PHYSICAL SERVICES TO: Mayor & Members of Council FROM: Ed Roloson, Manager of Capital Projects- Water/Wastewater Ops. DATE: January 5, 2023 REPORT: PS-01/23 SUBJECT: RFT 22-02 ONE (1) NEW HALF-TON FOUR WHEEL DRIVE PICKUP TRUCK BACKGROUND On October 4, 2022, the Council of the Corporation of the Municipality of Bayham passed the following motion, in part: Moved by: Councillor Chilcott Seconded by: Deputy Mayor Weisler THAT Report TR-16/22 re 2023-2032 Capital Budget - Draft be received for information; AND THAT Council approve the fourteen (14) Capital items identified in Report TR-16/22 for 2023 procurement. The 2023 Capital Budget includes the following:  Capital Item No. W-02 - $40,000 DISCUSSION On November 28, 2022, the Municipality of Bayham issued RFT 22-02 for One (1) New Half-Ton Four Wheel Drive Pickup Truck. RFT 22-02 closed on December 19, 2022 with the results as follows: Bidder Total Vehicle Cost Barrhaven Ford, Nepean, ON $61,464.73 + HST Blue Mountain Chrysler Ltd., Collingwood, ON $57,384.00 + HST Eichenberg Motors Ltd, Tillsonburg, ON $51,937.73 + HST The Lowest Compliant Bid is that of Eichenberg Motors Ltds., out of Tillsonburg at $51,937.73 + HST. Staff are recommending approval of this Bid. All received bids were above the cap for the Capital Item and are evidence of ongoing inflationary pressures over the calendar year. The overage to acquire the new half-ton four-wheel-drive pick-up will be covered via the Wastewater Reserve. RECOMMENDATION 1. THAT Report PS-01/23 re RFT 22-02 One (1) New Half-Ton Four Wheel Drive Pickup Truck be received for information; 2. AND THAT Council approve the procurement of One (1) New Half-Ton Four Wheel Drive Pickup Truck from Eichenberg Motors Ltd. in the total amount of $51,937.73+HST. Respectfully Submitted by: Reviewed by: _________________________ __________________________ Ed Roloson Thomas Thayer, CMO Manager of Capital Projects – CAO/Clerk Water/Wastewater Operations REPORT FIRE DEPARTMENT TO: Mayor & Members of Council FROM: Harry Baranik, Fire Chief Ed Roloson, Manager of Capital Projects – Water/Wastewater Ops. DATE: January 5, 2023 REPORT: FR-01/23 SUBJECT: CAPITAL ITEM NO. FD-02 – WATER FLOW SURVEY BACKGROUND On October 5, 2021, the Council of the Corporation of the Municipality of Bayham passed the following motion: THAT Report TR-12/21 re 2022-2031 Capital Budget - Draft be received for information; AND THAT Council approve in principle the 2022-2031 Capital Budget. The 2022 Capital Budget included Capital Item No. FD-02, for a total budget allotment of $29,000. Staff Report FR-04/22 was presented to Council on March 3, 2022. Council passed the following motion: THAT Report FR-04/22 re Awarding Contract for Fire Hydrant Flow Survey be received for information; AND THAT Council approves the award of the Fire Hydrant Flow Survey to SCG Flowmetrix; AND THAT the appropriate by-law to enter into an Agreement with SCG Flowmetrix for the Fire Hydrant Flow Survey be brought before Council for enactment. DISCUSSION The attached Fire Flow Testing Report conducted by SCG Flowmetrix details the fire flow testing results as per the NFPA 291. A total of sixty-eight (68) fire hydrants across Port Burwell and Vienna were successfully tested. The purpose of the testing was to create a known flow rate demand within the water distribution, which causes the static water pressure to drop to 20 psi. The results of the testing determines the available water flow rates in the event of a fire as well as determines the areas of low pressure that can lead to temporary water disruption to our users. The contents of this report are particularly important for fire protection, where water demand is acutely higher than normal demand periods. The Bayham Fire Department uses water from Vienna and/or Port Burwell hydrants to support their operations and fire suppression efforts when required and must be aware of flow constraints in the hydrant system. Two variables that can be present during the time of the testing are the day-to-day water demands as well as the height of the water tower located along Nova Scotia Line. NFPA 291 recommends that fire hydrants be colour-coded to a standard that visually identifies the available flow rate. The said recommended colour coding and firefighting rating is as follows (GPM = Gallons Per Minute): - Blue – 1500< GPM = Very Good - Green – 1000 – 1499 GPM = Good - Orange – 500 – 999 GPM = Marginal - Red – <500 GPM = Inadequate Based on the above, the Municipality currently has 79% of the hydrants rated as orange, 10% as blue, 8% as green, and 3% as red. A map is attached, denoting the Red hydrant locations, being the two (2) hydrants on Soper Road, south of Light Line. With the majority of our water system fire hydrants scoring as Marginal, adequate fire protection can be met under normal operations with minimal disruption to our drinking water customers. It should be noted, however, that modern pumpers will draw water at up to 1060 GPM, which is over the upper limit of the Marginal category and as such, only 18% of hydrants currently meet the full abilities of a department pumper. This does not mean the Marginal hydrants cannot be used; it, instead, means that the hydrants and water distribution systems were installed in an era where pumpers were not as powerful and pumper technology has since surpassed the technology of the day. If at a future date, staff and Council seek to improve the water distribution system to improve the rating of select hydrants, capital works will be required to increase the size of mains to permit greater flows. Drinking water system compliance and fire protection concerns have been identified and effectively managed by both the Water Department and Fire Services to ensure the needs of the community are being met. ATTACHMENTS 1. Fireflow Testing Results – Municipality of Bayham – December 2022 2. Map – Red Hydrants – Soper Road, Vienna RECOMMENDATION 1. THAT Report FR-01/23 re: Capital Item No. FD-02 – Water Flow Survey be received for information. Respectfully Submitted by: _________________________________ ___________________________ Harry Baranik Ed Roloson Fire Chief Manager of Capital Projects|Water & Wastewater Reviewed by: _______________________________ Thomas Thayer, CMO CAO|Clerk Prepared for: Municipality Of Bayham December 2022 FIRE FLOW TESTING REPORT December 8, 2022 Ed Roloson Manager of Capital Projects – Water/Wastewater Operations Municipality of Bayham P.O Box 160, 56169 Heritage Line Straffordville, ON NOJ 1Y0 P: 519-874-4761 E: eroloson@bayham.on.ca RE: FIRE FLOW TESTING IN THE MUNICIPALITY OF BAYHAM Dear Mr. Roloson, SCG Flowmetrix appreciated the opportunity to perform fire flow testing in the municipality of Bayham. SCG Flowmetrix representative conducted fire flow testing practices based on the NFPA 291. The purpose of the testing was to create a known flow rate demand in the distribution system, which causes the static pressure to drop to 20 psi. The flow rate (measured in gallons per minute) required to cause the overall pressure drop is the practical fire flow test rating of the hydrant under test. Tests were performed in four days from October 17, 2022, to October 20, 2022, by SCG Flowmetrix’s field representative Mr. Jordan Whitlock. The total number of hydrants in Vienna and Port Burwell communities is eighty-four (84). Sixty-eight (68) hydrants were tested successfully for the first part of testing, In Vienna, there were ten (10) hydrants (#39,41,42,45,81,64,53,67,48 and 71) located on a dead end, which couldn’t be tested due to false residual readings. In Port Burwell, six (6) hydrants remained untested of which 4 of them (#84,33,31 and 78) were located on a dead end. Also, hydrant #77 couldn’t be opened because of seized rod valve, so to avoid any damage to the hydrant the operator advised against testing. Hydrant #79 was owned by OCWA, and the OCWA operator was required to operate the hydrant. During the first day of testing, it was realized that the flow in the hydrants was low and opening two ports at the flow hydrant could cause the residual pressure to drop below 20 psi which is not recommended by NFPA 291. So, from the second day, only one port flowed for testing to keep the residual pressure above 20 psi. Based on the results, the fire flow test rating for all hydrant locations is more than 500 GPM. Please refer to Appendix A for testing results. Upon the client’s request on-site, a couple of hydrants were retested for the second part of testing. Those hydrants have the, closed interconnect valve, which connects Vienna and Port Burwell on the opposite side of the water feed. The purpose was to investigate the effect of opening valves on the booster pump and pressure in the watermain. So, the pressure monitoring locations on opposite ends of each community were selected, and the hydrant with the open interconnector valve flowed. The interconnector valve is located where Vienna and Port Burwell loop back from the farthest side of the watermain feed. For Port Burwell, one logger was installed on hydrant #24 to capture the main feed going into the community. Then hydrant #33 was selected, which was the furthest hydrant from the main watermain feed. The third logger was installed at hydrants #13, 22, and 36, near each flow test location. The results show the open valve. The booster is triggered, causing slightly less pressure drop compared to when the valve was closed. Please refer to Appendix B for testing results. For Vienna, one logger was installed on hydrant #24, and the second was installed on hydrant #72, which was located right next to the booster. The third logger recorded the lowest pressure, at the end of the watermain on hydrant #70. Then by flowing hydrants #68, 43, and 50, for hydrant #24, the pressure drop was less than when the valve was closed. But for hydrant #72, the pressure drop was significantly higher; at hydrant #70, the residual pressure dropped to zero. Please refer to Appendix C for testing results. Thank you for allowing SCG Flowmetrix to conduct fire flow testing in the Municipality of Bayham. If you have any questions or concerns about this project, please contact me at your convenience to discuss. Best regards, Farzaneh Kheirandish Project Coordinator SCG Flowmetrix Technical Services T: 226-213-7273 E: fkheirandish@SCGflowmetrix.com Appendix A Fire Flow Testing Results – All Hydrants in Vienna and Port Burwell RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1472 1474 737 2.5 Round 6.0 736 737 77 2 2.5 Round 6.0 736 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1517 HYDRANT OUTLET NOZZLE PITOT PITOT 75 BLUE 76.2 23.0 53.2 69.8 MAKE Century MODEL Mueller TIME 11:35 AM ADDRESS 1 Chatham St Fire Flow Testing Report Residual Hydrant #75 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200 1400 1600 1800 2000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1472 1474 737 2.5 Round 6.0 736 737 77 2 2.5 Round 6.0 736 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1521 HYDRANT OUTLET NOZZLE PITOT PITOT 76 BLUE 83.9 23.8 60.2 71.7 MAKE Century MODEL Mueller TIME 11:35 AM ADDRESS 1 Chatham St Fire Flow Testing Report Residual Hydrant #76 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200 1400 1600 1800 2000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1479 1481 741 2.5 Round 6.0 740 741 75 2 2.5 Round 6.0 740 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1440 HYDRANT OUTLET NOZZLE PITOT PITOT 30 GREEN 61.2 17.9 43.3 70.8 MAKE McAvity MODEL Brigadier TIME 12:10 PM ADDRESS 5 Chatham St Fire Flow Testing Report Residual Hydrant #30 NFPA Colour Code GREEN DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200 1400 1600 1800 2000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1479 1481 741 2.5 Round 6.0 740 741 75 2 2.5 Round 6.0 740 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1487 HYDRANT OUTLET NOZZLE PITOT PITOT 29 GREEN 60.1 20.4 39.7 66.1 MAKE McAvity MODEL Brigadier TIME 12:10 PM ADDRESS 19 Chatham St Fire Flow Testing Report Residual Hydrant #29 NFPA Colour Code GREEN DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200 1400 1600 1800 2000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1402 1404 702 2.5 Round 5.4 701 702 29 2 2.5 Round 5.4 701 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1427 HYDRANT OUTLET NOZZLE PITOT PITOT 27 GREEN 60.5 21.3 39.2 64.8 MAKE McAvity MODEL Brigadier TIME 12:35 PM ADDRESS 43 Chatham St Fire Flow Testing Report Residual Hydrant #27 NFPA Colour Code GREEN DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200 1400 1600 1800 2000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1402 1404 702 2.5 Round 5.4 701 702 29 2 2.5 Round 5.4 701 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1509 HYDRANT OUTLET NOZZLE PITOT PITOT 25 BLUE 58.2 24.9 33.4 57.3 MAKE McAvity MODEL Brigadier TIME 12:35 PM ADDRESS 53 Chatham St Fire Flow Testing Report Residual Hydrant #25 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200 1400 1600 1800 2000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1273 1275 637 2.5 Round 4.5 636 637 31 2 2.5 Round 4.5 636 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1416 HYDRANT OUTLET NOZZLE PITOT PITOT 28 GREEN 61.0 27.3 33.7 55.2 MAKE McAvity MODEL Brigadier TIME 1:00 PM ADDRESS 44 Addison St Fire Flow Testing Report Residual Hydrant #28 NFPA Colour Code GREEN DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200 1400 1600 1800 2000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1273 1275 637 2.5 Round 4.5 636 637 31 2 2.5 Round 4.5 636 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1420 HYDRANT OUTLET NOZZLE PITOT PITOT 26 GREEN 57.5 26.9 30.6 53.2 MAKE McAvity MODEL Brigadier TIME 1:00 PM ADDRESS 24 Addison St Fire Flow Testing Report Residual Hydrant #26 NFPA Colour Code GREEN DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200 1400 1600 1800 2000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1488 1490 745 2.5 Round 6.1 744 745 26 2 2.5 Round 6.1 744 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1554 HYDRANT OUTLET NOZZLE PITOT PITOT 24 BLUE 56.6 22.8 33.7 59.6 MAKE McAvity MODEL Brigadier TIME 1:20 PM ADDRESS 55461 Nova Scotia Lin Fire Flow Testing Report Residual Hydrant #24 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 0 500 1000 1500 2000 2500Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1619 1621 811 2.5 Round 7.2 810 811 24 2 2.5 Round 7.2 810 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1578 HYDRANT OUTLET NOZZLE PITOT PITOT 32 BLUE 57.0 18.2 38.8 68.0 MAKE McAvity MODEL Brigadier TIME 2:45 PM ADDRESS 55451 Nova Scotia Lin Fire Flow Testing Report Residual Hydrant #32 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 0 500 1000 1500 2000 2500Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1680 1682 841 2.5 Round 7.8 840 841 19 2 2.5 Round 7.8 840 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1639 HYDRANT OUTLET NOZZLE PITOT PITOT 18 BLUE 70.3 17.7 52.6 74.9 MAKE McAvity MODEL Brigadier TIME 3:10 PM ADDRESS 67 Robinson Fire Flow Testing Report Residual Hydrant #18 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 500 1000 1500 2000 2500Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1680 1682 841 2.5 Round 7.8 840 841 19 2 2.5 Round 7.8 840 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1851 HYDRANT OUTLET NOZZLE PITOT PITOT 23 BLUE 76.3 29.2 47.0 61.7 MAKE McAvity MODEL Brigadier TIME 3:10 PM ADDRESS 5 Bridge St Fire Flow Testing Report Residual Hydrant #23 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 500 1000 1500 2000 2500Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1636 1638 819 2.5 Round 7.4 818 819 21 2 2.5 Round 7.4 818 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1668 HYDRANT OUTLET NOZZLE PITOT PITOT 20 BLUE 69.9 21.8 48.1 68.9 MAKE McAvity MODEL Brigadier TIME 3:35 PM ADDRESS 38 Robinson St Fire Flow Testing Report Residual Hydrant #20 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 500 1000 1500 2000 2500Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1636 1638 819 2.5 Round 7.4 818 819 21 2 2.5 Round 7.4 818 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1750 HYDRANT OUTLET NOZZLE PITOT PITOT 19 BLUE 70.7 26.0 44.7 63.3 MAKE McAvity MODEL Brigadier TIME 3:35 PM ADDRESS 52 Robinson St Fire Flow Testing Report Residual Hydrant #19 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 500 1000 1500 2000 2500Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1594 1596 798 2.5 Round 7.0 797 798 14 2 2.5 Round 7.0 797 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1613 HYDRANT OUTLET NOZZLE PITOT PITOT 16 BLUE 71.8 21.1 50.6 70.6 MAKE McAvity MODEL Brigadier TIME 4:00 PM ADDRESS 23 Pitt St Fire Flow Testing Report Residual Hydrant #16 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 500 1000 1500 2000 2500Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 1594 1596 798 2.5 Round 7.0 797 798 14 2 2.5 Round 7.0 797 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1626 HYDRANT OUTLET NOZZLE PITOT PITOT 21 BLUE 71.3 21.8 49.5 69.4 MAKE McAvity MODEL Brigadier TIME 4:00 PM ADDRESS 18 Robinson St Fire Flow Testing Report Residual Hydrant #21 NFPA Colour Code BLUE DATE Oct‐17‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 500 1000 1500 2000 2500Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 717 1436 1436 014 1 2.5 Round 22.6 717 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 873 HYDRANT OUTLET NOZZLE PITOT PITOT 13 ORANGE 66.6 34.3 32.4 48.6 MAKE McAvity MODEL Brigadier TIME 8:40 AM ADDRESS 32 Strachen St Fire Flow Testing Report Residual Hydrant #13 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 717 1436 1436 014 1 2.5 Round 22.6 717 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 885 HYDRANT OUTLET NOZZLE PITOT PITOT 17 ORANGE 67.5 35.4 32.2 47.6 MAKE McAvity MODEL Brigadier TIME 8:40 AM ADDRESS 33 Erieus St Fire Flow Testing Report Residual Hydrant #17 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 716 1433 1433 014 1 2.5 Round 22.5 716 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 878 HYDRANT OUTLET NOZZLE PITOT PITOT 9 ORANGE 66.6 34.7 31.9 47.9 MAKE McAvity MODEL Brigadier TIME 9:00 AM ADDRESS 45 Wellington St Fire Flow Testing Report Residual Hydrant #9 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 716 1433 1433 014 1 2.5 Round 22.5 716 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 886 HYDRANT OUTLET NOZZLE PITOT PITOT 11 ORANGE 67.5 35.6 32.0 47.3 MAKE McAvity MODEL Brigadier TIME 9:00 AM ADDRESS 48 Shakespeare St Fire Flow Testing Report Residual Hydrant #11 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 709 1420 1420 014 1 2.5 Round 22.1 709 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 857 HYDRANT OUTLET NOZZLE PITOT PITOT 22 ORANGE 66.9 33.9 33.0 49.4 MAKE McAvity MODEL Brigadier TIME 9:20 AM ADDRESS 37 Pitt St Fire Flow Testing Report Residual Hydrant #22 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 709 1420 1420 014 1 2.5 Round 22.1 709 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 848 HYDRANT OUTLET NOZZLE PITOT PITOT 7 ORANGE 66.0 33.0 33.0 50.0 MAKE McAvity MODEL Brigadier TIME 9:20 AM ADDRESS 26 Victoria St Fire Flow Testing Report Residual Hydrant #7 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 717 1436 1436 014 1 2.5 Round 22.6 717 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 911 HYDRANT OUTLET NOZZLE PITOT PITOT 15 ORANGE 70.5 38.1 32.4 46.0 MAKE McAvity MODEL Brigadier TIME 9:38 AM ADDRESS 8 Strachen St Fire Flow Testing Report Residual Hydrant #15 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 743 1488 1488 015 1 2.5 Round 24.3 743 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 950 HYDRANT OUTLET NOZZLE PITOT PITOT 14 ORANGE 69.8 38.2 31.6 45.2 MAKE McAvity MODEL Brigadier TIME 9:52 AM ADDRESS 22 Strachen St Fire Flow Testing Report Residual Hydrant #14 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 442 885 885 084 1 2.5 Round 8.6 442 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 521 HYDRANT OUTLET NOZZLE PITOT PITOT 2 ORANGE 61.9 31.0 30.9 49.9 MAKE McAvity MODEL Brigadier TIME 10:20 AM ADDRESS 14 Elizabeth St Fire Flow Testing Report Residual Hydrant #2 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 442 885 885 084 1 2.5 Round 8.6 442 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 581 HYDRANT OUTLET NOZZLE PITOT PITOT 83 ORANGE 61.1 36.4 24.8 40.5 MAKE Century MODEL Mueller TIME 10:20 AM ADDRESS 40 Elizabeth St Fire Flow Testing Report Residual Hydrant #83 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700 800Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 526 1053 1053 033 1 2.5 Round 12.1 526 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 549 HYDRANT OUTLET NOZZLE PITOT PITOT 1 ORANGE 62.1 23.3 38.9 62.5 MAKE McAvity MODEL Brigadier TIME 10:40 AM ADDRESS 44 Wellington St Fire Flow Testing Report Residual Hydrant #1 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700 800Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 587 1176 1176 083 1 2.5 Round 15.2 587 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 639 HYDRANT OUTLET NOZZLE PITOT PITOT 82 ORANGE 59.5 25.8 33.8 56.7 MAKE Century MODEL Mueller TIME 11:15 AM ADDRESS 52 Elizabeth St Fire Flow Testing Report Residual Hydrant #82 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700 800 900Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 587 1176 1176 083 1 2.5 Round 15.2 587 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 669 HYDRANT OUTLET NOZZLE PITOT PITOT 3 ORANGE 59.1 28.4 30.7 52.0 MAKE Century MODEL Mueller TIME 11:15 AM ADDRESS 58 Elizabeth St Fire Flow Testing Report Residual Hydrant #3 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700 800 900Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 562 1126 1126 083 1 2.5 Round 13.9 562 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 704 HYDRANT OUTLET NOZZLE PITOT PITOT 6 ORANGE 63.3 34.7 28.6 45.2 MAKE McAvity MODEL Brigadier TIME 11:30 AM ADDRESS 48 Victoria St Fire Flow Testing Report Residual Hydrant #6 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700 800 900 1000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 562 1126 1126 0612.5 Round 13.9 562 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 712 HYDRANT OUTLET NOZZLE PITOT PITOT 10 ORANGE 65.1 36.0 29.1 44.7 MAKE Century MODEL Mueller TIME 11:30 AM ADDRESS 30 Waterloo St Fire Flow Testing Report Residual Hydrant #10 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700 800 900 1000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 729 1460 1460 0612.5 Round 23.4 729 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 857 HYDRANT OUTLET NOZZLE PITOT PITOT 5 ORANGE 61.8 30.8 31.0 50.1 MAKE McAvity MODEL Brigadier TIME 11:45 AM ADDRESS 62 Victoria St Fire Flow Testing Report Residual Hydrant #5 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 729 1460 1460 0412.5 Round 23.4 729 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 852 HYDRANT OUTLET NOZZLE PITOT PITOT 4 ORANGE 60.5 30.1 30.4 50.2 MAKE McAvity MODEL Brigadier TIME 11:45 AM ADDRESS 72 Victoria St Fire Flow Testing Report Residual Hydrant #4 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 533 1067 1067 0412.5 Round 12.5 533 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 618 HYDRANT OUTLET NOZZLE PITOT PITOT 8 ORANGE 61.7 30.0 31.7 51.4 MAKE McAvity MODEL Brigadier TIME 12:16 PM ADDRESS 102 Robinson St Fire Flow Testing Report Residual Hydrant #8 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700 800 900Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 533 1067 1067 0412.5 Round 12.5 533 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 667 HYDRANT OUTLET NOZZLE PITOT PITOT 12 ORANGE 66.7 35.9 30.9 46.3 MAKE McAvity MODEL Brigadier TIME 12:16 PM ADDRESS 63 Shakespeare St Fire Flow Testing Report Residual Hydrant #12 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700 800 900Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 536 1072 1072 0412.5 Round 12.6 536 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 636 HYDRANT OUTLET NOZZLE PITOT PITOT 34 ORANGE 59.5 30.7 28.7 48.3 MAKE McAvity MODEL Brigadier TIME 1:41 PM ADDRESS 4660 Plank Rd Fire Flow Testing Report Residual Hydrant #34 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700 800 900Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 536 1072 1072 035 1 2.5 Round 12.6 536 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 604 HYDRANT OUTLET NOZZLE PITOT PITOT 35 ORANGE 56.7 27.3 29.4 51.8 MAKE McAvity MODEL Brigadier TIME 1:41 PM ADDRESS 4895 Plank Rd Fire Flow Testing Report Residual Hydrant #35 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 0 100 200 300 400 500 600 700 800 900Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 503 1008 1008 035 1 2.5 Round 11.1 503 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 525 HYDRANT OUTLET NOZZLE PITOT PITOT 36 ORANGE 57.5 22.9 34.6 60.2 MAKE McAvity MODEL Brigadier TIME 2:05 PM ADDRESS 4968 Plank Rd Fire Flow Testing Report Residual Hydrant #36 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 503 1008 1008 037 1 2.5 Round 11.1 503 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 513 HYDRANT OUTLET NOZZLE PITOT PITOT 37 ORANGE 56.9 21.3 35.5 62.5 MAKE McAvity MODEL Brigadier TIME 2:05 PM ADDRESS 5026 Plank Rd Fire Flow Testing Report Residual Hydrant #37 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 0 100 200 300 400 500 600 700Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 502 1005 1005 037 1 2.5 Round 11.1 502 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 539 HYDRANT OUTLET NOZZLE PITOT PITOT 38 ORANGE 53.8 24.2 29.6 55.0 MAKE McAvity MODEL Brigadier TIME 2:15 PM ADDRESS 5364 Plank Rd Fire Flow Testing Report Residual Hydrant #38 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 0 100 200 300 400 500 600 700 800Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 633 1268 1268 072 1 2.5 Round 17.6 633 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 625 HYDRANT OUTLET NOZZLE PITOT PITOT 73 ORANGE 45.7 19.4 26.3 57.6 MAKE McAvity MODEL Brigadier TIME 3:15 PM ADDRESS 55113 Vienna Line Fire Flow Testing Report Residual Hydrant #73 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 0 100 200 300 400 500 600 700 800 900Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 633 1268 1268 072 1 2.5 Round 17.6 633 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 760 HYDRANT OUTLET NOZZLE PITOT PITOT 74 ORANGE 53.7 29.7 24.0 44.8 MAKE McAvity MODEL Brigadier TIME 3:15 PM ADDRESS 5634 Brown Rd Fire Flow Testing Report Residual Hydrant #74 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 707 1416 1416 065 1 2.5 Round 22.0 707 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 918 HYDRANT OUTLET NOZZLE PITOT PITOT 66 ORANGE 51.0 31.9 19.1 37.5 MAKE McAvity MODEL Brigadier TIME 3:45 PM ADDRESS 27 Centre St Fire Flow Testing Report Residual Hydrant #66 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200 1400Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 707 1416 1416 065 1 2.5 Round 22.0 707 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 963 HYDRANT OUTLET NOZZLE PITOT PITOT 72 ORANGE 48.1 32.3 15.9 33.0 MAKE McAvity MODEL Brigadier TIME 3:45 PM ADDRESS 13 Centre St Fire Flow Testing Report Residual Hydrant #72 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200 1400Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 615 1232 1232 064 1 2.5 Round 16.6 615 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 800 HYDRANT OUTLET NOZZLE PITOT PITOT 65 ORANGE 53.7 33.0 20.8 38.6 MAKE McAvity MODEL Brigadier TIME 4:05 PM ADDRESS 37 Centre St Fire Flow Testing Report Residual Hydrant #65 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 615 1232 1232 064 1 2.5 Round 16.6 615 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 806 HYDRANT OUTLET NOZZLE PITOT PITOT 54 ORANGE 54.0 33.4 20.7 38.2 MAKE McAvity MODEL Brigadier TIME 4:05 PM ADDRESS 42 Fulton St Fire Flow Testing Report Residual Hydrant #54 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 749 1499 1499 040 1 2.5 Round 24.6 749 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 1084 HYDRANT OUTLET NOZZLE PITOT PITOT 43 GREEN 79.4 49.5 29.9 37.7 MAKE McAvity MODEL Brigadier TIME 8:45 AM ADDRESS 9 Walnut St Fire Flow Testing Report Residual Hydrant #43 NFPA Colour Code GREEN DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200 1400Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 749 1499 1499 040 1 2.5 Round 24.6 749 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 943 HYDRANT OUTLET NOZZLE PITOT PITOT 44 ORANGE 79.2 40.6 38.6 48.8 MAKE McAvity MODEL Brigadier TIME 8:45 AM ADDRESS 48 Otter St Fire Flow Testing Report Residual Hydrant #44 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 692 1386 1386 041 1 2.5 Round 21.1 692 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 842 HYDRANT OUTLET NOZZLE PITOT PITOT 40 ORANGE 82.5 39.1 43.4 52.6 MAKE McAvity MODEL Brigadier TIME 9:20 AM ADDRESS 11 King St Fire Flow Testing Report Residual Hydrant #40 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 735 1473 1473 044 1 2.5 Round 23.8 735 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 910 HYDRANT OUTLET NOZZLE PITOT PITOT 47 ORANGE 79.9 39.5 40.4 50.5 MAKE McAvity MODEL Brigadier TIME 10:06 AM ADDRESS 6208 Plank Rd Fire Flow Testing Report Residual Hydrant #47 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 735 1473 1473 044 1 2.5 Round 23.8 735 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 969 HYDRANT OUTLET NOZZLE PITOT PITOT 46 ORANGE 81.0 44.4 36.6 45.2 MAKE McAvity MODEL Brigadier TIME 10:06 AM ADDRESS 2 Edison Dr Fire Flow Testing Report Residual Hydrant #46 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 713 1428 1428 046 1 2.5 Round 22.3 713 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 831 HYDRANT OUTLET NOZZLE PITOT PITOT 49 ORANGE 79.8 34.8 45.1 56.5 MAKE McAvity MODEL Brigadier TIME 10:32 AM ADDRESS 17 Edison Dr Fire Flow Testing Report Residual Hydrant #49 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 713 1428 1428 046 1 2.5 Round 22.3 713 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 862 HYDRANT OUTLET NOZZLE PITOT PITOT 58 ORANGE 80.3 37.9 42.4 52.8 MAKE McAvity MODEL Brigadier TIME 10:32 AM ADDRESS 32 Edison Dr Fire Flow Testing Report Residual Hydrant #58 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 734 1469 1469 058 1 2.5 Round 23.6 734 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 896 HYDRANT OUTLET NOZZLE PITOT PITOT 59 ORANGE 81.9 39.1 42.7 52.2 MAKE McAvity MODEL Brigadier TIME 10:50 AM ADDRESS 44 Edison Dr Fire Flow Testing Report Residual Hydrant #59 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 734 1469 1469 058 1 2.5 Round 23.6 734 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 916 HYDRANT OUTLET NOZZLE PITOT PITOT 61 ORANGE 74.8 38.5 36.3 48.5 MAKE McAvity MODEL Brigadier TIME 10:50 AM ADDRESS 51 Oak St Fire Flow Testing Report Residual Hydrant #61 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 783 1568 1568 059 1 2.5 Round 26.9 783 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 801 HYDRANT OUTLET NOZZLE PITOT PITOT 60 ORANGE 63.4 21.8 41.6 65.6 MAKE McAvity MODEL Brigadier TIME 11:26 AM ADDRESS 15 Chestnut St Fire Flow Testing Report Residual Hydrant #60 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 783 1568 1568 059 1 2.5 Round 26.9 783 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 768 HYDRANT OUTLET NOZZLE PITOT PITOT 62 ORANGE 58.1 18.6 39.5 68.0 MAKE McAvity MODEL Brigadier TIME 11:26 AM ADDRESS 24 Chestnut St Fire Flow Testing Report Residual Hydrant #62 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 674 1349 1349 060 1 2.5 Round 20.0 674 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 670 HYDRANT OUTLET NOZZLE PITOT PITOT 63 ORANGE 50.9 19.6 31.3 61.4 MAKE McAvity MODEL Brigadier TIME 11:45 AM ADDRESS 39 Union St Fire Flow Testing Report Residual Hydrant #63 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 0 100 200 300 400 500 600 700 800 900 1000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 674 1349 1349 060 1 2.5 Round 20.0 674 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 712 HYDRANT OUTLET NOZZLE PITOT PITOT 55 ORANGE 53.3 23.2 30.1 56.4 MAKE McAvity MODEL Brigadier TIME 11:45 AM ADDRESS 16 Ann St Fire Flow Testing Report Residual Hydrant #55 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 0 100 200 300 400 500 600 700 800 900 1000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 733 1468 1468 060 1 2.5 Round 23.6 733 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 914 HYDRANT OUTLET NOZZLE PITOT PITOT 56 ORANGE 61.9 34.0 27.9 45.0 MAKE McAvity MODEL Brigadier TIME 12:20 PM ADDRESS 27 Oak St Fire Flow Testing Report Residual Hydrant #56 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 733 1468 1468 060 1 2.5 Round 23.6 733 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 967 HYDRANT OUTLET NOZZLE PITOT PITOT 51 ORANGE 61.8 36.8 25.0 40.5 MAKE McAvity MODEL Brigadier TIME 12:20 PM ADDRESS 15 Oak St Fire Flow Testing Report Residual Hydrant #51 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200 1400Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 659 1320 1320 051 1 2.5 Round 19.1 659 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 678 HYDRANT OUTLET NOZZLE PITOT PITOT 52 ORANGE 51.1 21.6 29.5 57.8 MAKE McAvity MODEL Brigadier TIME 2:01 PM ADDRESS 24 Fulton St Fire Flow Testing Report Residual Hydrant #52 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 0 100 200 300 400 500 600 700 800 900 1000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 659 1320 1320 051 1 2.5 Round 19.1 659 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 671 HYDRANT OUTLET NOZZLE PITOT PITOT 80 ORANGE 51.8 21.0 30.8 59.5 MAKE McAvity MODEL Brigadier TIME 2:01 PM ADDRESS 13 Union St Fire Flow Testing Report Residual Hydrant #80 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 0 100 200 300 400 500 600 700 800 900 1000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 729 1461 1461 049 1 2.5 Round 23.4 729 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 841 HYDRANT OUTLET NOZZLE PITOT PITOT 50 ORANGE 73.0 32.3 40.7 55.8 MAKE McAvity MODEL Brigadier TIME 2:15 PM ADDRESS 16 Elm St Fire Flow Testing Report Residual Hydrant #50 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 90.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 547 1095 1095 070 1 2.5 Round 13.1 547 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 793 HYDRANT OUTLET NOZZLE PITOT PITOT 69 ORANGE 41.2 30.6 10.7 25.9 MAKE McAvity MODEL Brigadier TIME 2:30 PM ADDRESS 6347 Plank Rd Fire Flow Testing Report Residual Hydrant #69 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 547 1095 1095 070 1 2.5 Round 13.1 547 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 787 HYDRANT OUTLET NOZZLE PITOT PITOT 68 ORANGE 44.8 32.2 12.7 28.2 MAKE McAvity MODEL Brigadier TIME 2:30 PM ADDRESS 6385 Plank Rd Fire Flow Testing Report Residual Hydrant #68 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 549 1099 1099 071 1 2.5 Round 13.2 549 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 574 HYDRANT OUTLET NOZZLE PITOT PITOT 70 ORANGE 32.4 21.0 11.5 35.3 MAKE McAvity MODEL Brigadier TIME 3:00 PM ADDRESS 6545 Soper Rd Fire Flow Testing Report Residual Hydrant #70 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 696 1394 1394 050 1 2.5 Round 21.3 696 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 749 HYDRANT OUTLET NOZZLE PITOT PITOT 57 ORANGE 65.5 25.8 39.7 60.6 MAKE McAvity MODEL Brigadier TIME 3:30 PM ADDRESS 27 Elm St Fire Flow Testing Report Residual Hydrant #57 NFPA Colour Code ORANGE DATE Oct‐19‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 100 200 300 400 500 600 700 800 900 1000Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book2 "If we don't measure it, how do you manage it?" Appendix B Fire Flow Testing Results – Port Burwell Tests With Open Interconnector Valve RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 715 1431 1431 014 1 2.5 Round 22.4 715 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 776 HYDRANT OUTLET NOZZLE PITOT PITOT 33 ORANGE 62.3 26.0 36.4 58.4 MAKE AVK MODEL 27/JA‐001 TIME 9:00 AM ADDRESS 56 Wellington St Fire Flow Testing Report Residual Hydrant #33 NFPA Colour Code ORANGE DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book3 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 714 1490 1490 014 1 2.5 Round 22.4 714 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 775 HYDRANT OUTLET NOZZLE PITOT PITOT 24 ORANGE 62.3 26.0 36.3 58.3 MAKE McAvity MODEL Brigadier TIME 9:00 AM ADDRESS 55461 Nova Scotia Lin Fire Flow Testing Report Residual Hydrant #24 NFPA Colour Code ORANGE DATE October 20, 2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book3 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 714 1436 1436 014 1 2.5 Round 22.4 714 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 909 HYDRANT OUTLET NOZZLE PITOT PITOT 13 ORANGE 69.6 37.9 31.7 45.5 MAKE McAvity MODEL Brigadier TIME 9:00 AM ADDRESS 32 Strachen St Fire Flow Testing Report Residual Hydrant #13 NFPA Colour Code ORANGE DATE October 20, 2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book3 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 676 1431 1431 0712.5 Round 20.1 676 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 822 HYDRANT OUTLET NOZZLE PITOT PITOT 33 ORANGE 62.2 32.8 29.4 47.3 MAKE AVK MODEL 27/JA‐001 TIME 9:30 AM ADDRESS 56 Wellington St Fire Flow Testing Report Residual Hydrant #33 NFPA Colour Code ORANGE DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book3 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 676 1490 1490 0712.5 Round 20.1 676 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 781 HYDRANT OUTLET NOZZLE PITOT PITOT 24 ORANGE 55.6 28.3 27.3 49.1 MAKE McAvity MODEL Brigadier TIME 9:30 AM ADDRESS 55461 Nova Scotia Lin Fire Flow Testing Report Residual Hydrant #24 NFPA Colour Code ORANGE DATE October 20, 2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book3 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 676 1420 1420 0712.5 Round 20.1 676 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 859 HYDRANT OUTLET NOZZLE PITOT PITOT 22 ORANGE 66.7 36.7 30.0 45.0 MAKE McAvity MODEL Brigadier TIME 9:30 AM ADDRESS 37 Pitt St Fire Flow Testing Report Residual Hydrant #22 NFPA Colour Code ORANGE DATE Oct‐18‐2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD.DIFFUSER DIFFUSER #TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 681 1431 1431 035 1 2.5 Round 20.4 681 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 933 HYDRANT OUTLET NOZZLE PITOT PITOT 33 ORANGE 61.9 38.5 23.4 37.8 MAKE AVK MODEL 27/JA‐001 TIME 9:45 AM ADDRESS 56 Wellington St Fire Flow Testing Report Residual Hydrant #33 NFPA Colour Code ORANGE DATE October 20, 2022 0.00 15.00 30.00 45.00 60.00 75.00 0 200 400 600 800 1000 1200 1400Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 681 1490 1490 035 1 2.5 Round 20.4 681 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 859 HYDRANT OUTLET NOZZLE PITOT PITOT 24 ORANGE 55.5 32.4 23.1 41.6 MAKE McAvity MODEL Brigadier TIME 9:45 AM ADDRESS 55461 Nova Scotia Lin Fire Flow Testing Report Residual Hydrant #24 NFPA Colour Code ORANGE DATE October 20, 2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book3 "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD. DIFFUSER DIFFUSER # TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 681 1008 1008 035 1 2.5 Round 20.4 681 ID (INCHES) (psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSET DIAMETER COEFFICIENT READING FLOW 876 HYDRANT OUTLET NOZZLE PITOT PITOT 36 ORANGE 56.5 33.6 22.9 40.5 MAKE McAvity MODEL Brigadier TIME 9:45 AM ADDRESS 4968 Plank Rd Fire Flow Testing Report Residual Hydrant #36 NFPA Colour Code ORANGE DATE October 20, 2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant Book3 "If we don't measure it, how do you manage it?" Appendix C Fire Flow Testing Results – Vienna Tests With Open Interconnector Valve RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD.DIFFUSER DIFFUSER #TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 612 1226 1226 06812.5 Round 16.5 612 ID (INCHES)(psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSETDIAMETER COEFFICIENT READING FLOW 1111 HYDRANT OUTLET NOZZLE PITOT PITOT 72 GREEN 47.3 38.2 9.0 19.1 MAKE McAvity MODEL Brigadier TIME 10:15 AM ADDRESS 13 Centre St Fire Flow Testing Report Residual Hydrant #72 NFPA Colour Code GREEN DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200 1400 1600Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD.DIFFUSER DIFFUSER #TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 612 1226 1226 06812.5 Round 16.5 612 ID (INCHES)(psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSETDIAMETER COEFFICIENT READING FLOW 909 HYDRANT OUTLET NOZZLE PITOT PITOT 24 ORANGE 55.4 38.4 17.0 30.7 MAKE McAvity MODEL Brigadier TIME 10:15 AM ADDRESS 55461 Nova Scotia Lin Fire Flow Testing Report Residual Hydrant # NFPA Colour Code 24 ORANGE DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200 1400Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD.DIFFUSER DIFFUSER #TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 612 1226 1226 06812.5 Round 16.5 612 ID (INCHES)(psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSETDIAMETER COEFFICIENT READING FLOW 472 HYDRANT OUTLET NOZZLE PITOT PITOT 70 RED 32.9 12.1 20.8 63.4 MAKE McAvity MODEL M67 TIME 10:15 AM ADDRESS 6545 Soper Rd Fire Flow Testing Report Residual Hydrant #70 NFPA Colour Code RED DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 0 100 200 300 400 500 600 700 800 900Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD.DIFFUSER DIFFUSER #TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 800 1602 1602 04312.5 Round 28.1 800 ID (INCHES)(psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSETDIAMETER COEFFICIENT READING FLOW 793 HYDRANT OUTLET NOZZLE PITOT PITOT 72 ORANGE 47.2 19.6 27.7 58.6 MAKE McAvity MODEL Brigadier TIME 10:30 AM ADDRESS 13 Centre St Fire Flow Testing Report Residual Hydrant # NFPA Colour Code 72 ORANGE DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD.DIFFUSER DIFFUSER #TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 800 1602 1602 04312.5 Round 28.1 800 ID (INCHES)(psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSETDIAMETER COEFFICIENT READING FLOW 974 HYDRANT OUTLET NOZZLE PITOT PITOT 24 ORANGE 55.3 30.8 24.6 44.4 MAKE McAvity MODEL Brigadier TIME 10:30 AM ADDRESS 55461 Nova Scotia Lin Fire Flow Testing Report Residual Hydrant # NFPA Colour Code 24 ORANGE DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200 1400Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD.DIFFUSER DIFFUSER #TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 800 1602 1602 04312.5 Round 28.1 800 ID (INCHES)(psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSETDIAMETER COEFFICIENT READING FLOW 482 HYDRANT OUTLET NOZZLE PITOT PITOT 70 RED 32.9 0.0 32.9 100.0 MAKE McAvity MODEL M67 TIME 10:30 AM ADDRESS 6545 Soper Rd Fire Flow Testing Report Residual Hydrant #70 NFPA Colour Code RED DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 0 100 200 300 400 500 600 700 800 900Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD.DIFFUSER DIFFUSER #TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 743 1487 1487 05012.5 Round 24.2 743 ID (INCHES)(psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSETDIAMETER COEFFICIENT READING FLOW 736 HYDRANT OUTLET NOZZLE PITOT PITOT 72 ORANGE 47.1 19.6 27.5 58.4 MAKE McAvity MODEL Brigadier TIME 10:45 AM ADDRESS 13 Centre St Fire Flow Testing Report Residual Hydrant # NFPA Colour Code 72 ORANGE DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD.DIFFUSER DIFFUSER #TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 743 1487 1487 05012.5 Round 24.2 743 ID (INCHES)(psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSETDIAMETER COEFFICIENT READING FLOW 925 HYDRANT OUTLET NOZZLE PITOT PITOT 24 ORANGE 55.3 31.8 23.5 42.5 MAKE McAvity MODEL Brigadier TIME 10:45 AM ADDRESS 55461 Nova Scotia Lin Fire Flow Testing Report Residual Hydrant # NFPA Colour Code 24 ORANGE DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 60.00 0 200 400 600 800 1000 1200 1400Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" RESIDUAL HYDRANT INFO. HYDRANT # N.F.P.A. COLOUR CODE STATIC PRESSURE psi RESIDUAL PRESSURE psi PRESSURE DROP psi % PRESSURE DROP % psi Flow on Water Main At Test Hydrant @ 20 psi USGPM FLOW HYDRANT(S) INFO. HYD.DIFFUSER DIFFUSER #TYPE COEFFICIENT PORTS LPD250 0.90 FIRE FLOW CHART COMMENTS OPERATOR FMX OPERATOR FMX OPERATOR Jordan Whitlock Bayham Municipality Total Flow 743 1487 1487 05012.5 Round 24.2 743 ID (INCHES)(psi) (USGPM) (Gal) TOTAL VOLUME  OF  WATERASSETDIAMETER COEFFICIENT READING FLOW 445 HYDRANT OUTLET NOZZLE PITOT PITOT 70 RED 32.6 0.0 32.6 100.0 MAKE McAvity MODEL M67 TIME 10:45 AM ADDRESS 6545 Soper Rd Fire Flow Testing Report Residual Hydrant #70 NFPA Colour Code RED DATE Oct‐20‐2022 0.00 15.00 30.00 45.00 0 100 200 300 400 500 600 700 800Pressure (PSI)Flow Rate (USGPM) Pressure ‐Flow Graph at Test Hydrant "If we don't measure it, how do you manage it?" ZBA-04/22 PLANNING ACT NOTICE OF THE PASSING OF ZONING BY-LAW Z752-2022 BY THE CORPORATION OF THE MUNICIPALITY OF BAYHAM APPLICANT: VIENNA FARMS LTD. ZBA-04/22 TAKE NOTICE that the Council of the Corporation of the Municipality of Bayham passed By- Law No. Z752-2022 on the 15th day of December 2022 under Section 34 of THE PLANNING ACT. AND TAKE NOTICE that any person or agency may appeal to the Ontario Land Tribunal in respect of the By-law by filing with the Clerk of the Municipality of Bayham not later than the 8th day of January 2023 a notice of appeal setting out the objection to the By-law and the reasons in support of the objection. THE PURPOSE of this By-law is to change the zoning on a 2.48 ha (6 acre) parcel of land from Agricultural (A1) Zone to a Site Specific Agricultural (A1-43) Zone to permit: large-scale supplementary farm dwelling use; maximum floor area of 306 square metres for the supplementary farm dwelling; minimum 2.3 ha (5.7 acres) farmland area worked per labourer; minimum lot area (existing) of 2.48 ha; minimum front yard depth for the existing dwelling of 10.8 metres whereas 15 metres is the permitted minimum; minimum front yard depth for the existing accessory building of 8.4 metres whereas accessory buildings are not permitted in a front yard or closer to the street than the main building is to the street; and minimum 0.9 metre setback for the existing accessory building (north side) whereas 1.0 metre is the permitted minimum in Zoning By-law Z456-2003. The subject lands are located on the west side of Plank Road, north of Glen Erie Line and known as 4964 and 4968 Plank Road. THE EFFECT of this By-law will be to permit a site-specific large scale supplementary farm dwelling use with maximum permanent building floor area exceeding the maximum floor area of 167 m² (1,797 ft2) in the Official Plan, to permit the year-round occupancy of the supplementary farm dwelling due to a longer growing season for apples and seasonal labourers employed during the winter months for the apple storage facility, to recognize the maximum land area worked per labourer for the farm operation, and to recognize existing front, rear and side yard setbacks for the dwelling and accessory buildings. Official Plan Amendment No. 28 was approved by Elgin County on November 9th, 2022, with no appeals filed within the statutory timeline, to permit the site-specific large scale supplementary farm dwelling, therefore rezoning can proceed. ONLY INDIVIDUALS, CORPORATIONS AND PUBLIC BODIES may appeal a by-law to the Ontario Land Tribunal. A notice of appeal may not be filed by an unincorporated association or group. However, a notice of appeal may be filed in the name of an individual who is a member of the association or the group on its behalf. NO PERSON OR PUBLIC BODY SHALL be added as a party to the hearing of the appeal unless, before the by-law was passed, the person or public body made oral submissions at a public meeting or written submissions to the council or, in the opinion of the Ontario Land Tribunal, there are reasonable grounds to add the person or public body as a party. The complete By-law is available for inspection by contacting the municipal office. DATED AT THE MUNICIPALITY OF BAYHAM THIS 19th DAY OF DECEMBER 2022. NOTE: For information regarding the fees associated with an appeal to the Ontario Land Tribunal, please see the following link: https://olt.gov.on.ca/appeals-process/fee-chart/ or contact the Municipality. Margaret Underhill Planning Coordinator/Deputy Clerk Municipality of Bayham 56169 Heritage Line, P.O. Box 160 Straffordville, ON, N0J 1Y0 T: 519-866-5521 Ext 222 F: 519-866-3884 E: munderhill@bayham.on.ca W: www.bayham.on.ca ZBA-03/22 PLANNING ACT NOTICE OF THE PASSING OF ZONING BY-LAW Z753-2022 BY THE CORPORATION OF THE MUNICIPALITY OF BAYHAM APPLICANT: BONNEFIELD CANADIAN FARMLAND LP III, ZBA-03/22 TAKE NOTICE that the Council of the Corporation of the Municipality of Bayham passed By- Law No. Z753-2022 on the 15th day of December 2022 under Section 34 of THE PLANNING ACT. AND TAKE NOTICE that any person or agency may appeal to the Ontario Land Tribunal in respect of the By-law by filing with the Clerk of the Municipality of Bayham not later than the 8th day of January 2023 a notice of appeal setting out the objection to the By-law and the reasons in support of the objection. THE PURPOSE of this By-law is to change the zoning on a 54 ha (134 acre) parcel of land from Agricultural (A1-A) Zone to a Site Specific Agricultural (A1-A-44) Zone to permit: a large scale supplementary farm dwelling use; supplementary farm dwelling maximum floor area of 322 square metres; the year-round operation of the supplementary farm dwelling; and minimum 2.3 ha (5.7 acres) farmland area worked per labourer for the farm operation, in Zoning By-law Z456- 2003. The subject lands are located on the south side of Chute Line, on the west side of Toll Gate Road and known as 56237 Chute Line. THE EFFECT of this By-law will be to permit a site-specific large scale supplementary farm dwelling use with maximum permanent building floor area exceeding the maximum floor area of 167 m² (1,797 ft2) in the Official Plan, to permit the year-round occupancy of the supplementary farm dwelling due to a longer growing season for apples and seasonal labourers employed during the winter months for the apple storage facility, and to recognize the maximum land area worked per labourer for the farm operation. Official Plan Amendment No. 29 was approved by Elgin County on November 9th, 2022, with no appeals filed within the statutory timeline, to permit the site-specific large scale supplementary farm dwelling, therefore rezoning can proceed. ONLY INDIVIDUALS, CORPORATIONS AND PUBLIC BODIES may appeal a by-law to the Ontario Land Tribunal. A notice of appeal may not be filed by an unincorporated association or group. However, a notice of appeal may be filed in the name of an individual who is a member of the association or the group on its behalf. NO PERSON OR PUBLIC BODY SHALL be added as a party to the hearing of the appeal unless, before the by-law was passed, the person or public body made oral submissions at a public meeting or written submissions to the council or, in the opinion of the Ontario Land Tribunal, there are reasonable grounds to add the person or public body as a party. The complete By-law is available for inspection by contacting the municipal office. DATED AT THE MUNICIPALITY OF BAYHAM THIS 19th DAY OF DECEMBER 2022. NOTE: For information regarding the fees associated with an appeal to the Ontario Land Tribunal, please see the following link: https://olt.gov.on.ca/appeals-process/fee-chart/ or contact the Municipality. Margaret Underhill Planning Coordinator/Deputy Clerk Municipality of Bayham 56169 Heritage Line, P.O. Box 160 Straffordville, ON, N0J 1Y0 T: 519-866-5521 Ext 222 F: 519-866-3884 E: munderhill@bayham.on.ca W: www.bayham.on.ca ZBA-09/22 REVISED NOTICE OF A PUBLIC MEETING CONCERNING A PROPOSED ZONING BY-LAW AMENDMENT IN THE MUNICIPALITY OF BAYHAM APPLICANT: CRAIG AND LISA LATIMER LOCATION: 54296 HERITAGE LINE TAKE NOTICE that the Municipality of Bayham has received a complete application for a Zoning By-law Amendment (ZBA-09/22). AND TAKE NOTICE that the Council of the Corporation of the Municipality of Bayham will hold a public meeting on Thursday, January 19, 2022 at 7:30 p.m. in the Municipal Council Chambers, 56169 Heritage Line in Straffordville to consider a proposed Zoning By-law amendment under Section 34 of the PLANNING ACT. The Meeting will allow for a hybrid meeting function – you may attend in person or watch virtually through the live-stream on the Municipality of Bayham’s YouTube Channel. If you wish to participate virtually, contact the undersigned no later than 48 hours in advance of the meeting and a Zoom link can be provided. THE PURPOSE of this By-law is to rezone a 3,844 m2 (0.95 acre) parcel of land from an Estate Residential (ER) zone to a site-specific Estate Residential (ER-xx) zone to permit a site-specific home occupation, agricultural use for onsite and home-based large agricultural vehicle repair with increased maximum floor area for an accessory building and Motor Vehicle Inspection Station (MVIS) use; to permit an accessory building maximum floor area for the proposed use and personal storage of 470.1 m2 (5,059.9 ft2) whereas 95 m2 or 8% lot coverage, whichever is greater, is the permitted maximum; and to permit maximum height for an accessory building of 6.7 m (22 ft) whereas 6.0 m (19.7 feet) is the permitted maximum, in Zoning By-law Z456-2003. The lands are located at 54296 Heritage Line, west of Culloden Road. THE EFFECT of this By-law will be to permit the operation of a small, owner-operated small business for the maintenance and repair of large agricultural vehicles inside the proposed oversized accessory building and as the base of operations for repairs offsite and storage of parts and repair equipment and to permit the owner to operate as part of the business a motor vehicle inspection station (MVIS) use to be authorized by the Ministry of Transportation. ANY PERSON may attend the public meeting and/or make a written or verbal representation in support of or in opposition to the proposed amendment. When possible, please consider utilizing written correspondence. Written comments are to be submitted on or before 12:00 Noon on Wednesday, January 11, 2023 to munderhill@bayham.on.ca or at the municipal office for inclusion in the public meeting agenda. IF A PERSON OR PUBLIC BODY does not make oral submissions at a public meeting or make written submissions to the Municipality of Bayham before the by-law is passed, the person or public body is not entitled to appeal the decision of the Council of the Corporation of the Municipality of Bayham to the Ontario Land Tribunal. IF A PERSON OR PUBLIC BODY does not make oral submissions at a public meeting or make written submissions to the Municipality of Bayham before the by-law is passed, the person or public body may not be added as a party to the hearing of an appeal before the Ontario Land Tribunal unless, in the opinion of the Tribunal, there are reasonable grounds to do so. IF YOU WISH to be notified of the adoption of the proposed amendment, you must make a written request to the undersigned. ADDITIONAL INFORMATION relating to the proposed amendment may be obtained at the Municipal Office. Dated at the Municipality of Bayham this 19th day of December 2022. Margaret Underhill Planning Coordinator/Deputy Clerk Municipality of Bayham 56169 Heritage Line, P.O. Box 160 Straffordville, ON, N0J 1Y0 T: 519-866-5521 Ext 222 F: 519-866-3884 E: munderhill@bayham.on.ca W: www.bayham.on.ca REPORT DEVELOPMENT SERVICES TO: Mayor & Members of Council FROM: Thomas Thayer, CMO, CAO|Clerk DATE: January 5, 2023 REPORT: DS-02/23 FILE NO. SUBJECT: 4TH QUARTER REPORT BACKGROUND The purpose of this report is to inform Council of the activities of the Building Services Department and Drainage file for Q4 2022 and 2022 year-end. DISCUSSION Building Services: The summary of building permits issued in Q4 2022 are as listed on the chart below: Year 2022 2021 2020 No. permits issued 21 37 35 Permit fees $20,484 $50,951 $46,526 Construction Value $1,702,000 $7,745,100 $4,297,000 Houses 0 7 9 Farm Buildings 0 3 3 Other 21 27 23 Total Building Permits for 2022: Year 2022 2021 2020 No. permits issued 160 189 178 Permit fees $192,034 $211,373 $170,408 Construction Value $28,404,000 $23,800,385 $16,705,855 Houses 33 35 23 Farm Buildings 8 6 12 Other 119 148 143 Council will note the marked decrease in Building activity in Q4 compared to earlier in 2022, including 0 permits issued for houses for the first quarter in over 6 years. It is likely that this slow-down in building activity is due, at least in part, to the interest rate hikes witnessed in 2022, which affect borrowing of all types, including construction. Drainage: A review of the ongoing drainage files was conducted with input from Steve Adams, Manager of Public Works|Drainage Superintendent. rainage work for the fourth quarter of 2022 is noted below: New Drains: Drain Name Status Hampton Drain Reassessment ongoing, pending berm construction by private landowner previously assessed on the file. New Drain – Peters Drain extension Engineer review and assessment ongoing through Spriet Associates as directed by Council. Drain Maintenance: Drain Name Status Bartley Drain A Clear backed up tile and outlet. Bartley Drain B Maintenance to address SWM pond drainage concern. RECOMMENDATION 1. THAT Staff Report DS-02/23 re 4th Quarter Report be received for information. Respectfully Submitted by: _________________________________ Thomas Thayer, CMO CAO|Clerk Legislative Services Town of Newmarket 395 Mulock Drive clerks@newmarket.ca P.O. Box 328 Station Main tel.: 905-895-5193 Newmarket, ON L3Y 4X7 fax: 905-953-5100 December 15, 2022 Sent via email RE: Bill 23, More Homes Built Faster Act, 2022 I am writing to advise you that at the Council meeting held on December 12, 2022, Council adopted the following recommendations regarding the above referenced matter: Whereas the Government of Ontario recently passed Bill 23, More Homes Built Faster Act, 2022 without providing meaningful or adequate opportunity for municipalities to provide input on ways to increase the supply of housing and to improve housing affordability in Ontario while ensuring the financial capacity of municipalities to support growth and protection of the environment; and, Whereas Bill 23 will have significant negative impact on heritage housing, green standards, environmental protection of wetlands, conservation, social housing and other significant areas of concern; and, Whereas a preliminary analysis of Bill 23 by the Association of Municipalities of Ontario (AMO) indicates the transfer of up to $1 billion a year in costs from private sector developers to property taxpayers without any likelihood of improved housing affordability while also undermining environmental protection; and, Whereas the Town of Newmarket has been specifically identified as a growth area, with a target to introduce 12,000 new homes by 2031, despite a lack of sewage capacity until the southern solution as mandated by the province is completed; and, Whereas municipal estimates vary between a property tax impact of Bill 23 between five and 15 per cent; and, Whereas a growing number of municipalities have joined in expressing their concern with the negative impacts of Bill 23; Legislative Services Town of Newmarket 395 Mulock Drive clerks@newmarket.ca P.O. Box 328 Station Main tel.: 905-895-5193 Newmarket, ON L3Y 4X7 fax: 905-953-5100 Therefore be it resolved, 1. That the Town of Newmarket formally express its opposition to Bill 23 in its current form and that this resolution be forwarded to the Premier, the Minister of Municipal Affairs and Housing Steve Clark, and MPP Newmarket-Aurora Dawn Gallagher- Murphy; and, 2. That the Town of Newmarket formally submits its inability to meet the stated target of 12,000 new homes by 2031; and, 3. That a copy of this resolution also be sent to the Association of Municipalities of Ontario, and all Ontario municipalities. Yours sincerely, Kiran Saini Deputy Clerk Copy: Association of Municipalities of Ontario All Ontario municipalities 318 Canborough St. P.O. Box 400 Smithville, ON L0R 2A0 T: 905-957-3346 F: 905-957-3219 www.westlincoln.ca December 13, 2022 City of Niagara Falls 4310 Queen Street Niagara Falls, ON L2E 6X5 Attn: Bill G. Matson, City Clerk Dear Mr. Matson: RE: “Bill 23, The More Homes for Everyone Act, 2022” This is to confirm that at the Dec 12, 2022 Council Meeting the following resolution was adopted with respect to the above noted matter: WHEREAS the Council of the Township of West Lincoln receive and support the correspondence, dated November 22, 2022, from the City of Niagara Falls regarding "Bill 23, The More Homes for Everyone Act, 2022"; AND WHEREAS Council appreciates and understands that the lack of attainable and affordable housing is an important issue facing the entire Province; AND WHEREAS Bill 23 will have economic, social,and environmental implications that will affect several acts including but not limited to the Conservation Authorities Act, Development Charges Act, 1997, Municipal Act, 2001, Ontario Heritage Act, Ontario Land Tribunal Act, 2021, Planning Act and may make changes to the Ontario Building Code along with the financial burden that this legislation will have on municipalities and existing homeowners; NOW THEREFORE BE IT RESOLVED that the Council of the Township of West Lincoln concurs with City of Niagara Falls Council and many others that the legislative program under the umbrella of the Ontario Housing Supply Action Plan must be paused in order to have a more in-depth consultation with municipalities and other stakeholders; AND THAT this resolution be forwarded to the Honourable Doug Ford, Premier of Ontario, the Honourable Steve Clark, Minister of Municipal Affairs and Housing, the Honourable David Piccini, Minister of the Environment, Conversation and Parks, the Honourable Graydon Smith, Minister of Natural Resources and Forestry, the Honourable Peter Tabuns, Leader of the Opposition and Interim Leader of the Ontario New Democratic Party, the Honourable John Fraser Interim Leader of the Ontario Liberal Party, the Honourable Mike Schreiner, Leader of the Green Party of Ontario, the Association of Municipalities of Ontario (AMO) and all Ontario municipalities . If any further information is required, please contact the undersigned at 905-957-3346, Ext 5136. Yours Truly, Joanne Scime Director of Legislative Services/Clerk cc. Honourable Doug Ford, Premier of Ontario Honourable Steve Clark, Minister of Municipal Affairs and Housing Honourable David Piccini, Minister of the Environment, Conversation and Parks, Honourable Graydon Smith, Minister of Natural Resources and Forestry, Honourable Peter Tabuns, Leader of the Opposition and Interim Leader of the Ontario New Democratic Party Honourable John Fraser Interim Leader of the Ontario Liberal Party Honourable Mike Schreiner, Leader of the Green Party of Ontario Association of Municipalities of Ontario (AMO) Ontario municipalities The Corporation of the City of Cambridge Corporate Services Department Clerk’s Division The City of Cambridge 50 Dickson Street, P.O. Box 669 Cambridge ON N1R 5W8 Tel: (519) 740-4680 ext. 4585 mantond@cambridge.ca December 21, 2022 Re: City of Cambridge - Opposition to Bill 23, More Homes Built Faster Act Municipalities of Ontario, At the Special Council Meeting of December 15, 2022, the Council of the Corporation of the City of Cambridge passed the following Motion: Moved By: Councillor Roberts Seconded By: Councillor Hamilton Whereas the More Homes Built Faster Act received Royal Assent on November 28, 2022; and Whereas these changes that will have significant impacts on several provincial Acts and in turn, significant and longstanding impacts on Ontario municipalities; and Whereas the Act defines affordable housing as 80% of the market rate; and Whereas a definition of affordability which is tied to a percentage of market rates remains largely unaffordable for many; and Whereas the province has restricted the use of inclusionary zoning by limiting it to 5% of dwellings within a development, thereby limiting affordable housing opportunities; and Whereas the province has restricted the use of inclusionary zoning by capping the time to remain affordable at 25 years, thereby limiting the longevity of housing affordability; and Therefore, be it resolved that the Cambridge City Council requests that the provincial definition of affordable be based on income and not market rates, and Be it further resolved that the Cambridge City Council requests that the provincial limitation of 5% of the use of inclusionary zoning within a development be increased; and Be it further resolved that the Cambridge City Council requests that the provincial timelines regarding the use of inclusionary zoning affordable housing be increased beyond 25 years; Be it further resolved that the Cambridge City Council requests that the Province reconsider how the More Homes Built Faster Act, 2022, will negatively impact environmental protection, heritage preservation, public participation, and loss of farmland; and Be it further resolved that Cambridge City Council also supports the resolution passed on December 8, 2022 by the Ontario Big City Mayors regarding the More Homes Built Faster Act. Should you have any questions related to the approved resolution, please contact me. Yours Truly, Danielle Manton City Clerk Cc: (via email) Hon. Premier Ford Ministry of Municipal Affairs and Housing Ontario MP’s and MPP’s Association of Municipalities of Ontario All Ontario Municipalities City of Cambridge Council To: Hon. Doug Ford, Premier Hon. Steve Clark, Minister of Municipal Affairs and Housing Hon. Michael Parsa, Associate Minister of Housing December 6, 2022 RE: Bill 23 More Homes Built Faster Act The Municipality of North Perth appreciates that housing is a top priority for the Province and shares the desire for more homes, especially affordable homes. However, following a high-level review of the proposed legislation, the Municipality of North Perth believes that Bill 23 will do little to accomplish this goal. Firstly, we appreciate the opportunity to provide comments on this matter, but find it important to acknowledge that staff and Council of the Municipality require more than 30 days to digest and respond to a complex piece of legislation affecting nine existing Acts. North Perth was disappointed to learn that Bill 23 received Royal Assent on November 28, 2022, despite the Province extending the comment period to December 9th. The Municipality feels that this further proves that although municipalities are the most informed on local housing issues, the Province does not view them as a strategic partner in solution finding and action. As outlined below, the Municipality of North Perth has several concerns to date with the legislation. The bill, as it is currently written, would eliminate the charges that developers currently pay toward housing. This will eliminate hundreds of millions of dollars that municipalities rely on for housing programs and dramatically reduce municipal affordable housing efforts. Development Charges (DC) are designed to help municipalities pay for a portion of the capital infrastructure required to support new growth, to ensure that existing taxpayers are not required to subsidize costs of the infrastructure or services needed to support new residents and businesses. Without a new revenue stream to offset DC payments, the legislation hampers the ability of municipalities to fund and deliver growth-related infrastructure. The changes to the Development Charges Act fundamentally impacts municipalities’ ability to ensure growth pays for growth. The changes to the various Acts have significant financial impacts on Ontario’s municipalities along with their respective taxpayers. It is anticipated that these changes will put additional pressure on property taxes and water and wastewater rates. Property taxes and user fees are crafted to fund projects and programs that communities need, however adding more costs to existing property owners will increase their costs and could negatively impact their ability to keep their current housing affordable. Provincial legislation should not unduly burden homeowners and renters to guarantee the long-term success of solving the housing crisis. Municipalities are extremely limited in the ways that they can collect revenue, relying on transfers from other levels of government to mitigate property tax rate increases, fund critical infrastructure and balance annual budgets. Municipalities already face an infrastructure funding gap that requires additional financial investments, resources and supports. Planning for increasing additional dwelling units will place more strain on water and wastewater systems which will require upgrading to increase capacity. This will require additional financial resources to manage, at a time when municipalities are already facing increased budgetary pressures due to inflationary costs, increased citizen expectations and the transfer of responsibilities from the Province. Without additional funding or resources from the Province to offset these costs, municipalities will have little option but to put these costs back on the taxpayer. The amendment that all DC by-laws passed after January 1, 2022 (previously June 1, 2022) must be phased-in for the first five years that the by-law is in force will have an overall negative consequence to the goal of building more housing. The phase-in will delay necessary infrastructure projects to unlock growth while also providing incentives for development projects to be delayed until a new by- law is enacted. Growth-related infrastructure often centres on the infrastructure itself, but a critical piece towards infrastructure is the land required to build. Land represents a significant cost for some municipalities in the purchase of property to provide services to new residents. This is a cost required due to growth and should be funded by new development. Studies, such as Official Plans, are required to establish when, where and how a municipality will grow. These growth-related studies should remain funded by growth. Master Plans and environmental assessments are essential to understand the servicing needs that development will place on hard infrastructure; again, these are necessary studies to inform the servicing required to establish the supply of lands for development. This would restrict the supply of serviced land and would contradict the province’s intent to create additional housing units. Parkland dedication levies exist to ensure that municipal park systems grow alongside other community developments. Increasing the supply and mix of housing is an important goal that we all share; however, sufficient access to parks and greenspace cannot be overlooked as we try to create meaningful alternatives to single-family dwellings. Municipalities already face challenges with the supply of adequate parkland due to the rising costs of land and current limitations under the Planning Act relative to municipal parkland standards. Upper-tier and single-tier municipalities across the province utilize DCs to help fund the construction of new affordable housing units with the goal of providing affordable housing to those in need. The removal of housing services and limiting the tools available to municipalities to support homeless and underhoused people and families will reduce municipality participation in creating affordable housing units, putting further burden on municipal taxpayers. In order for the Province to successfully achieve the goal of building 1.5 million homes within the next ten years, municipalities must be viewed as strategic partners. As the frontline level of government, municipalities are also eager to resolve the housing crisis and are the most informed on what is needed to create complete communities that the people of Ontario want and expect. Please consider revisions to the regulations in Bill 23 for more meaningful review and consultation with stakeholders and input from municipalities, and conduct thorough analyses of both short and long-term impacts. To ensure informed implementation of this proposal, alternatives to improve the legislation to effectively create more attainable housing for Ontario need to be considered. Sincerely, Todd Kasenberg, Mayor Municipality of North Perth 330 Wallace Ave. N Listowel, ON N4W 1L3 toddkasenberg@northperth.ca CC: MPP Matthew Rae Environmental Registry of Ontario All Ontario Municipalities     December 2022   We've made it to the 12th and final chapter of 2022- what a year it's been! Amidst all the uncertainty and unfamiliarity, there have been so many moments of delight as we've finally been able to resume the activities and traditions we hold dear. It's been so good to see you again, Elgin County! As we take stock of a year almost complete we are deeply grateful to be part of such an incredible community. Now more than ever, the impacts of prioritizing shopping local make a huge difference. Wherever possible, please consider looking a little closer to home for the items on your shopping list- these purchases help to support the heart of our communities and ensure strong local economies now and in the future. From all of us at Elgin County Economic Development and Tourism, we wish you a very Merry Christmas and a prosperous New Year. Have a magical December in Elgin! Congratulations to Natterjack Brewing Company Ltd. in West Elgin, who recently received a Gold award in the Smoked Beer category at the Ontario Brewing Awards ceremony in Toronto! Their 'Logger' beer is a must-try, along with the rest of their incredible locally- made lineup! Check them out and shop online here Earth + Honeybee There are new beekeepers on the scene in Elgin County, and the community is already abuzz! Husband and wife duo Melissa and Adam are new residents in Union, having just arrived from the Ilderton area in October 2022, and they are already establishing a strong local presence at farmers' markets and through their online shop. The couple's passion for environmental stewardship is evident in everything they do, but most significantly in the way they work with and for the bees in their care. Cultivating spiritual ties with bees allows one to be able to connect with nature in a vulnerable way, says Melissa. In caring for the hive you start to deeply understand the role bees play in the broader ecosystem and to use all your senses to appreciate their contributions. One thing Melissa enjoys most about beekeeping is the way that it becomes meditative, through the hum of the bees and routine of their care. She reflects that being amidst an active hive of bees makes you feel like you're stopped in time. Seeing them living with such structure and instinct, serving a collective benefit that's greater than any one bee, is an inspiring metaphor for life. These are all lessons that the couple has learned in a relatively short amount of time, having first started keeping bees as a hobby born from a brainstorming session in 2017. At that time, they were looking for hobbies they could share but also potentially turn into a business. Melissa thought about beekeeping, and it all started rolling from there, eventually leading to her leaving her career in mental health to serve the business full-time while Adam continues to work for the City of London. The process has all seemed quite natural and symbolic, almost predestined! Since Melissa was a child, she has been interested in name meanings, with hers being 'honeybee'. Adam's means 'red earth,' so the combination of the two inspired the business name. Education is at the core of Earth + Honeybee's identity. Melissa and Adam love to help people learn more about honeybees, give them more confidence in starting or continuing their beekeeping journeys, and providing access to affordable equipment and bee byproducts that people may not otherwise be able to find. They are passionate about inviting people to see firsthand how deeply they care for their hives as working members of the operation, with bee health and welfare as their top priority. The couple hopes that by learning about and experiencing beekeeping firsthand, people can become more connected to the original roots of self-sustenance and join the network of humans taking an active role in supporting pollinators. This, they feel, is connected to broader activities and values that include soil maintenance through composting, wellness and meditation, and planting pollinators. They plan to facilitate these educational and healing encounters through experience-based opportunities at their new property in Union as well as virtual workshops. Through sharing their love for bees and beekeeping, Melissa and Adam are building a pretty incredible community! With a strong start and big goals for the future, Earth + Honeybee is a great new addition to Elgin County. Please check them out at their website below and look for them at a market near you in 2023! Earth + Honeybee 6039 Fairview Rd., St. Thomas, ON N5P 3S8 519-494-8070 Email: Earth.Honeybee@gmail.com Shop online with local pickup or find them at a local market Website Paleta Passion Another new Elgin business with a very fitting name is Paleta Passion, now with a lovely storefront on Talbot Street in Aylmer! Owner Christina Friesen, an Aylmer native, spent part of her childhood in Mexico and was inspired to start a small business centred on a nostalgic sweet treat from her time there. The paleta is a Mexican frozen treat made from either fresh natural fruits or rich, creamy ingredients, and it plays a strong role in the country's cultural tradition. Christina remembers how exciting it was to enjoy paletas as a child and notes that in Mexico there is a great deal of regional flavour variation, since they traditionally use fruits that are local and in season. If the ultimate Mexican paleta taste-testing road trip isn't in the cards for you anytime soon, a trip to 81 Talbot St E in Aylmer is very close to being the real deal! Christina jumped right into the creative freedom of crafting new flavours. She developed a blueberry paleta that is unique because blueberries are not grown in Mexico! The most popular flavour among customers who come from a Mexican background is horchata, while those new to the paleta seem to favour mango. With Christmas flavours in-store now, this is the perfect holiday venture with the family. Christina has big plans for the future and will continue to pop up at local markets throughout the summer season in addition to operating the new store. This is definitely one to watch, and we strongly recommend keeping her in mind for your next corporate event or party! Congratulations, Christina, we are excited to see where this new venture takes you! Paleta Passion 81 Talbot St. E, Aylmer, ON 226-231-2615 Email: paletapassion@gmail.com Open Tuesday-Saturday 1pm-6pm, open until 9pm Fridays Website Here is the menu! Stop by in-store for the list of seasonal offerings. Southwestern Ontario Development Fund The newest SWODF application intake will be open from January 12, 2023 to February 23, 2023. You can find more information about eligibility and the intake process HERE For advice on developing and strengthening your application, you are encouraged to contact your regional advisor or Business Advisory Services at: Business Advisory Services - Western Region Main Office westernregionbas@ontario.ca Toll-free: 1-800-267-6592 Canada Summer Jobs Canada Summer Jobs provides wage subsidies to employers with 50 or fewer full-time employees to create quality summer work experiences for young people aged 15-30 years. Applications are open until January 12, 2023 and more details are available HERE Business Scale-up and Productivity- FedDev Ontario Thinking of taking things to the next level? Funding under this stream helps to accelerate the growth of firms and assist with the adoption of new, innovative technologies that support scale-up, productivity, adn the development of and entry into new markets to help companies become globally competitive. More details HERE Community Economic Development and Diversification- FedDev Ontario Funding is available to businesses and not-for-profit organizations in small communities who are working to develop, diversify, and transform their local economies. DETAILS Are you an Immigrant or Racialized Person who has Experienced Discrimination in St. Thomas or Elgin County in the Last Three Years? If you are, and you have experienced discrimination in a Workplace Setting, in a Public Place, or By the Police, please consider participating in a virtual interview with researchers at Western University. By sharing your stories and feedback, you will help communities across the region become more inclusive and welcoming. If you are interested in participating, please fill out a short survey and the researchers will contact you. We want to hear from you! If you operate a tourism-related business in Elgin County, the department would greatly appreciate your taking the time to complete our quick survey summarizing the summer 2022 tourism season HERE. Thanks so much for your consideration! ​Have an opportunity you'd like us to share? Please send details to economicdevelopment@elgin.ca Is 2023 the year you start working toward a new business or a new business growth goal? When was the last time you brushed up your business plan, or are you on the journey without your map? This FREE four-part Business Planning Boot Camp is designed to support entrepreneurs to refresh their plan or start from scratch with the support needed to polish it up too. Because if you are looking for funds, you are going to need a plan. If you are looking to grow, you are going to need a plan. If you are looking to start, this is the starting line. Join Sarah and Elle from the St. Thomas-Elgin Small Business Enterprise Centre in January to start the new year strong! Signup here Provincial Government Updates On November 14, the Ontario Government released the 2022 Ontario Economic Outlook and Fiscal Review - Ontario's Plan to Build: A Progress Update. It included the government's progress report on previous budgetary commitments, as well as new measures including support for small businesses. Key highlights: Providing over $675M in Ontario income tax relief over 3 years by temporarily allowing eligible businesses to immediately expense up to $1.5M per year for certain capital investments Proposing to extend the phase-out range for the small business Corporate Income Tax rate to between $10M and $50M of taxable capital Proposing to expand eligible expenditures for the Ontario Productions Services Tax Credit to include location fees Establishing consultation groups to support refocused red tape reduction efforts, inviting representatives from key industries and areas of activity across the province Proposing legislation to launch a voluntary Clean Energy Credit registry Proposing amendments to the Securities Act to enable digital access to documents On November 23, the Provincial Ministry of Red Tape Reduction introduced the Less Red Tape, Stronger Ontario Act, which includes 28 new measures to increase Ontario's competitiveness, support stronger supply chains, and make government easier to access and interact with. Read the backgrounder here Highlights of the package include: Removing legislative barriers to support greater investment in clean and emission reducing technologies. Providing more data and tools to municipalities to determine optimal Reduced Load Periods on roadways and improve supply chain efficiency. Increasing court capacity and efficiency to improve service, including the introduction of digital jury questionaries. Modernizing the Veterinarians Act, including identifying opportunities to streamline requirements or reduce compliance burden for vets and practice owners. The Act also included the creation of the Grow Ontario Strategy, which outlines the province's plan to strengthen the agri-food sector, ensure an efficient, reliable, and responsive food supply and address ongoing vulnerabilities through new innovations. The plan focuses on three key priorities: Strengthen Agri-food Supply Chain Stability: Increase both the consumption and production of food grown and prepared in Ontario by 30 per cent, increase Ontario’s food and beverage manufacturing GDP by 10 per cent and boost Ontario’s agri-food exports eight per cent annually by 2032. This includes opening applications for the $10 million Food Security and Supply Chain Fund which will provide funding for projects such as updated inventory software, expanded warehousing to allow increased inventory levels or automation equipment to address labour gaps. The province is also strengthening its food processing capacity and food security to position the sector for growth through the $25 million Strategic Agri-Food Processing Fund. Increase Agri-food Technology and Adoption: Boost research infrastructure, advance the uptake of new technologies, grow the market for Ontario innovative technologies domestically and globally, and grow the use of data to support efficiencies in the agri-food sector and value chain. The province will also begin consultations on modernizing the Agricultural Research Institute of Ontario Act to fuel innovation and support efforts to provide modern, relevant research information to farmers and agri-food businesses. Attract and Grow Ontario’s Agri-food Talent: The province aims to increase total agri-food sector employment by 10 per cent by 2032, as well as increase awareness of modern, high-tech agri-food careers, opportunities for mentorship and hands-on job training, and support efforts to increase veterinary capacity in underserviced areas of the province. This includes launching public consultations to explore opportunities to modernize the Veterinarians Act as part of the plan to increase access to veterinary care in Ontario. On November 22, the Economic Development and Tourism team attended the Aylmer Chamber of Commerce's Business After 5 networking event held in the future home of the Aylmer-Malahide Museum and Archives. It was a great opportunity to connect with some familiar faces and hear about all the exciting things happening in the Aylmer business community! Members of the Economic Development team attended the 2022 Growing Your Workforce conference hosted in partnership with the Western Ontario Wardens' Caucus. Members of the team also attended the St. Thomas and District Chamber of Commerce's Annual General Meeting on November 30. Saturdays and Sundays in December- Port Stanley Terminal Rail Treats Trains Saturdays in December- Old Imperial Farmers' Market Christmas Market Saturday, December 17- Holidays at Sparta Lavender Farm Saturday, December 17- Sip and Shop Market at London Waffle Co. January Business after 5 hosted by the St. Thomas & District Chamber of Commerce, January 18- Details Have an event you'd like us to share? Please send details to economicdevelopment@elgin.ca Elgin County Economic Development & Tourism | www.elgincounty.ca Elgin County | 450 Sunset Drive, St. Thomas, N5R 5V1 Canada Unsubscribe economicdevelopment@elgin.ca Update Profile |Constant Contact Data Notice Sent byinfo@elgin.capowered by Try email marketing for free today! Long Point Region Conservation Authority 4 Elm St., Tillsonburg, Ontario N4G 0C4 519-842-4242 or 1-888-231-5408 ˖ Fax 519-842-7123 Email: conservation@lprca.on.ca ˖ www.lprca.on.ca A Member of the Conservation Ontario Network December 13, 2022 Municipality of Bayham P.O. Box 160, 56169 Heritage Line Straffordville, ON N0J 1Y0 Via email: MElliott@bayham.on.ca Re: 2023 Draft LPRCA Budget_________________________________________________ To the Mayor and Council, In response to your letter dated December 9, 2022 requesting clarification on the nature of the expenditure increases and the impacts to the 2023 draft consolidated operating budget the main drivers are identified as follows: a) Compensation Expenditures: The Authority had and independent external consultant conduct a Pay Equity & Compensation Review in 2022 (last review conducted in 2012) which found at the 50th percentile the Authority was 11.5% behind the comparators. The LPRCA Board of Directors approved the consultants report and the new adjusted pay grid at the October meeting. Additionally, the 2023 COLA for staff wages included in the draft budget is 6.0%. COLA is based on the 12-month average of the CPI from September through August. This method has historically been used to be applied to the pay grid. b) Conservation Authorities Act Regulatory Changes: The amended act requires conservation authorities to have in place the following plans by December 31, 2023: i. Conservation Lands Management Strategy Plan, ii. Land Inventory Registry Plan, iii. Ice Management Plan, iv. Asset Management Plan (water control structures) and v. Water Resources Management Plan. LPRCA has already commenced initial work on developing these required plans. The 2023 draft budget includes the addition of two contract part-time positions (1.07 FTE’s) to lead the initiative to complete the plans. Completing the plans in-house was selected over using a consultant not only because of the cost effectiveness but a staff member who has helped the Authority to fill staffing gaps and training new staff that A Member of the Conservation Ontario Network has the expertise & knowledge of the organization and watershed has agreed to remain on staff to lead these projects during this transition period. c) Campground and Motorpool Capital: The 2023 draft budget will recover campground and motorpool capital requirements from current year surplus instead of relying on levying our municipal partners for these capital items. In previous budgets current year surplus was used to support (decrease) current year municipal operating levy. This change resulted in a decrease in year-over-year capital levy to our municipal partners of $231,000 or 60.7% and an increase of $231,000 in municipal operating levy. The amended regulations effective January 1, 2024 changes the method conservation authorities can levy for capital and LPRCA adapted these changes in advance of the requirement. d) Other items that impacted overall expenditures: Insurance premiums 10% increase over 2022 actuals, employee benefits 15% increase over 2022 actuals, OMERS non- full-time expansion, increase in both CPP and EI rates and overall inflationary pressures. Thank you for your inquiry. I trust this correspondence provides sufficient clarification as to the main drivers of the increases of the 2023 draft budget operating expenditure increase and the impacts to the 2023 draft consolidated budget. If you have any further questions please give me call at 519-842-4242 ext. 225. Regards, Judy Maxwell, CPA, CGA General Manager/Secretary-Treasurer REPORT CAO TO: Mayor & Members of Council FROM: Thomas Thayer, CAO|Clerk DATE: January 5, 2023 REPORT: CAO-02/23 SUBJECT: PORT BURWELL LIGHTHOUSE HERITAGE AND STRUCTURAL ASSESSMENT BACKGROUND At its November 3, 2022 meeting, Council received Report CAO-63/22 re Port Burwell Lighthouse Heritage Cladding Assessment Report. The Report provided Council with a comprehensive background of the project to-date and advised that, per the Heritage Cladding Assessment Report, prepared by a+LINK Architecture Inc. (a+LINK), further assessment was required, including the following items:  Architectural Report and Cladding Review  Structural Report  Soil Test Report  Topographical Survey, which would be further used to establish conservation and maintenance plans for the Port Burwell Lighthouse. The a+LINK Report identified that remediation should be the focus rather than replacement, and includes the complete removal of the existing vinyl application, which has contributed significantly to the observed deteriorated condition of the wood siding. Upon of Report CAO-63/22, Council passed the following motion: Moved by: Councillor Chilcott Seconded by: Councillor Donnell THAT Report CAO-63/22 re Port Burwell Lighthouse Heritage Cladding Assessment Report be received for information; AND THAT cost estimates for the recommended items in the Heritage Cladding Assessment Report be obtained and provided to Council for further consideration. On December 21, 2022, staff received a formal Proposal for the Heritage Assessment, Structural Assessment, and Digital Scanning services from a+LINK. The Proposal is attached to this Report. The soil test and updated topographical survey were handled operationally in Q4 2022. Council is also aware that the Municipality was a recipient of $100,000 grant through the Southwest Tourism Relief Fund (STRF) for exterior works at the Port Burwell Lighthouse. The works through the STRF grant must have been completed and substantiated by year-end 2022. DISCUSSION The Proposal covers two of the four recommended processes discussed in Report CAO-63/22, being the Architectural Report and Cladding Review, and the Structural Report. Digital Scanning Services is a stand-alone item that would apply to the former as a part of a comprehensive analysis process should there be any physical documentation requiring digitization. The total proposed costing is $19,935.00. Should Council opt to proceed, the outstanding works would take six (6) week and would be capped with a Report. Given the timeline provided, the Report would be received by staff by the end of February 2023 and would be received by Council in March 2023. Staff recommend proceeding with the Proposal provided by a+LINK to ensure this important work is actioned in the short-term. Regarding the STRF grant, staff have confirmed two points for Council’s information: 1) The grant cannot be extended past the December 31, 2022 deadline; and, 2) any background works regarding studies for future Lighthouse works are eligible under the STRF’s funding so long as these costs were incurred and invoiced prior to December 31, 2022. In accordance and in November 2022, staff obtained costing and completed the soil test and topographical survey updates for the Port Burwell Lighthouse. Total costs for these works were approximately $9,000 and will be recouped through the STRF as well as costs incurred for the previously-received Heritage Cladding Assessment Report. Total recouped costs are estimated at $14,200. The survey has since been provided to a+LINK for their use moving forward, should Council opt to approve the Proposal. ATTACHMENTS 1. Proposal from a+LINK – Port Burwell Lighthouse – Heritage Architectural Services for the Port Burwell Lighthouse Recladding Project - Cladding Review, Structural Report, and Preparation of Existing Condition Drawings RECOMMENDATION 1. THAT Report CAO-02/23 re Port Burwell Lighthouse Heritage and Structural Assessment be received for information; 2. AND THAT Council accept the Proposal for Heritage Architectural Services for the Port Burwell Lighthouse Recladding Project - Cladding Review, Structural Report, and Preparation of Existing Condition Drawings in the amount of $19,935.00. Respectfully Submitted by: Thomas Thayer, CMO CAO|Clerk 126 WELLINGTON ROAD LONDON ON N6C 4M8 519.649.0220 www.aLiNKarch.ca preserve + create + sustain 1 2022-12-21 Municipality of Bayham By Email: cao@bayham.on.ca 56169 Heritage Line, PO Box 160 Straffordville, ON N0J 1Y0 Att: Thomas Thayer, MSc, CMO, Chief Administrative Officer | Clerk Re: Request for Quotation (RAF001) Heritage Architectural Services for the Port Burwell Lighthouse Recladding Project Cladding Review, Structural Report, and Preparation of Existing Condition Drawings a+LiNK Project: 2238 (2201-74) Dear Thomas, Thank you for giving our firm the opportunity to provide you with a proposal of heritage architectural services and fees for the Port Burwell Lighthouse Recladding Project; specifically Cladding Review, Structural Report, and Preparation of Existing Condition Drawings as outlined in the recommendations section 5.1 of the previous report. We submit our proposal as follows for your consideration: Scope of Work Our scope of work for services to Architectural and Heritage Scope of Work  perform one (1) site visit for investigation  prepare a cladding report  review of existing vinyl coating paint removal testing and options  provision of drawings (cut from scanned Building Information Model)  plans at each landing datum  elevations  roof plan  sections Structural Engineering  subconsulting services – John Cooke Engineering  perform one (1) site visit for investigation  prepare engineering report Scanning Services  subconsulting services – Reprodux Digigal Scanning  perform one (1) site visit for investigation  document site conditions of the lighthouse; interior and exterior elements, with a final point cloud deliverable in RCP format.  3D generic BIM building model. 126 WELLINGTON ROAD LONDON ON N6C 4M8 519.649.0220 www.aLiNKarch.ca preserve + create + sustain 2 Legal Name of Prime Consultant a+LiNK Architecture Inc. 126 Wellington Street London, Ontario N6C 4M8 t: 519.649.0220 Principals and Staff Directly Involved in the Project Principal in Charge: Ed van der Maarel, Principal Architect, Heritage Consultant + Partner Design Lead: Timothy Finch, Heritage Consultant + Licensed Technologist Heritage CAD: Hadi Tamin, Intern Heritage Consultant, BIM List of Sub Consultants Structural Engineering John Cooke Engineering Digital Scanning Reprodux Project Schedule We are available to begin the project within two (2) weeks of award and provide a report within four (4) weeks of starting the work, total six (6) weeks. Schedule of Professional Fees We propose consulting fees for the services as per the following breakdown: Heritage Architectural Services $ 10,160.00 Structural Engineering Services $ 5,700.00 Digital Scanning Services $ 4,075.00 Disbursements (Travel Budget 2 trips) $ included TOTAL $ 19,935.00 Disbursements Included: as described above Changes to Scope of Work The following is a schedule of fees which apply to changes to the scope of work. Changes to the scope of work must be approved in writing by both parties prior to proceeding with the work. a+LiNK Architecture Inc. Principal Architect $ 195.00 per hour Principal Heritage Architect $ 205.00 per hour 126 WELLINGTON ROAD LONDON ON N6C 4M8 519.649.0220 www.aLiNKarch.ca preserve + create + sustain 3 Senior Heritage Architect $ 145.00 per hour Project Architect (Associate) $ 135.00 per hour Intern Architect $ 120.00 per hour Senior Licensed Technologist $ 120.00 per hour Intermediate CAD Technologist $ 100.00 per hour Interior Designer $ 100.00 per hour Junior $ 85.00 per hour Clerical $ 65.00 per hour Specialized Consultants Principal Heritage Architect $ 205.00 per hour LEED Consultant $ 205.00 per hour Value Added Tax: The Harmonized Sales Tax @ 13% will be applied to all invoices. Invoicing: Invoicing will occur on a monthly basis as the work proceeds. Note: Notwithstanding the foregoing, the obligations and liabilities of the Architect are limited to the professional liability insurance provided by Pro-Demnity Insurance Company and any specific or excess professional liability insurance coverage in force. We look forward to working with you on this project. Should you have any questions regarding this proposal please do not hesitate to contact us 519.649.0220. Sincerely, Ed J. van der Maarel Principal Architect, Partner Dip. Arch., Dip. Arch.Tech., OAA, CAHP Acceptance of Proposal Signature Print Name Date THE CORPORATION OF THE MUNICIPALITY OF BAYHAM BY-LAW NO. 2023-001 A BY-LAW TO CONFIRM ALL ACTIONS OF THE COUNCIL OF THE CORPORATION OF THE MUNICIPALITY OF BAYHAM FOR THE COUNCIL MEETING HELD JANUARY 5, 2023 WHEREAS under Section 5 (1) of the Municipal Act, 2001 S.O. 2001, Chapter 25, the powers of a municipal corporation are to be exercised by the Council of the municipality; AND WHEREAS under Section 5 (3) of the Municipal Act, 2001, the powers of Council are to be exercised by by-law; AND WHEREAS the Council of The Corporation of the Municipality of Bayham deems it advisable that the proceedings of the meeting be confirmed and adopted by by-law. THEREFORE THE COUNCIL OF THE CORPORATION OF THE MUNICIPALITY OF BAYHAM ENACTS AS FOLLOWS: 1. THAT the actions of the Council of The Corporation of the Municipality of Bayham in respect of each recommendation and each motion and resolution passed and other action by the Council at the Council meeting held January 5, 2023 is hereby adopted and confirmed as if all proceedings were expressly embodied in this by-law. 2. THAT the Mayor and Clerk of The Corporation of the Municipality of Bayham are hereby authorized and directed to do all things necessary to give effect to the action of the Council including executing all documents and affixing the Corporate Seal. READ A FIRST, SECOND AND THIRD TIME AND FINALLY PASSED THIS 5th DAY OF JANUARY 2023. ____________________________ _____________________________ MAYOR CLERK